14Technical data
2.If necessary, adjust the door. Refer to "Installation".
3.If necessary, replace the defective door gaskets. Contact the Service Center.
TECHNICAL DATA
Dimension |
|
|
|
|
|
|
|
|
| Height | 815 mm |
|
|
|
|
|
| Width | 596 mm |
|
|
|
|
|
| Depth | 550 mm |
|
| ||
Rising Time |
|
| 29 h |
|
| ||
Voltage |
|
| |
|
| ||
Frequency |
|
| 50 Hz |
|
|
|
|
The technical information are situated in the rating plate on the internal left side of the appliance and in the energy label.
INSTALLATION
WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the appli- ance before installing the appliance.
Positioning
This appliance can be installed in a dry, well ventilated indoor (garage or cellar) also, but for optimum performance install this appliance at a location where the ambient temperature corresponds to the climate class indicated on the rating plate of the appliance:
Climate class |
| Ambient temperature |
|
|
|
SN |
| +10°C to + 32°C |
|
|
|
N |
| +16°C to + 32°C |
|
|
|
ST |
| +16°C to + 38°C |
|
|
|
T |
| +16°C to + 43°C |
|
|
|
Electrical Connection
CAUTION!
Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability should these safety measures not be observed.