Mounting more than one hob

Distance to wall:

Min. 150 mm (flammable material)

Reinforcement beam

Distance to wall:

Min. 50 mm

(non-flammable material)

 

m

 

m

 

0

9

4

 

Cutting out

The measurement of the selected combination is calculated in the following way:

Depth: 490 mm

Width:

1.Calculate the sum of all units’ width.

2.Subtract 20 mm from the total width.

Example:

A hob of 720 mm + a downdraft of 180 mm + a gas hob of 360 mm.

1.720+180+360= 1260 mm

2.Width of the hole: 1260-20=1240 mm

Distance to Wall:

Min. 150 mm to flammable material.

Min. 50 mm to non-flammable material