To clean the drain pump:

1 2

1.Open the drain pump door.

2.Put a container below the recess of the drain pump to collect the water that flows out.

3.Press the two levers and pull forward the drainage duct to let the water flow out.

4.When the container is full of water, put the drainage duct back again and empty the container. Do steps 3 and 4 again and again until no more wa- ter flows out from the drain pump.

5.Pull back the drainage duct and turn the filter to remove it.

6.Remove fluff and objects from the pump.

7.Make sure that the impeller of the pump can turn. If this does not occur, contact the service centre.