AEG L 75270 FL, L 75670 FL, L 75470 FL user manual Inlet Hose Filter, Valve Filter, Emergency Drain

Models: L 75270 FL L 75470 FL L 75670 FL

1 36
Download 36 pages 47.21 Kb
Page 25
Image 25

2

1

ENGLISH 25

9.Clean the filter under the water tap and put it back in the pump into the special guides.

10.Make sure that you tighten correct- ly the filter to prevent leakages.

11.Put the flap back and close the drain pump door.

THE INLET HOSE FILTER AND

• The indicator of button

4

flashes

THE VALVE FILTER

and the display shows the

related

It could be necessary to clean the filters

alarm. Refer to 'Troubleshooting'.

WARNING!

when:

Disconnect the mains plug from

• The appliance does not fill with wa-

the mains socket.

ter.

 

 

 

The appliance fills with the water for a long time.

To clean the water inlet filters:

1. Close the water tap.

2. Remove the water inlet hose from the water tap.

3. Clean the filter in the inlet hose with a stiff brush.

4. Remove the inlet hose behind the appliance.

5. Clean the filter in the valve with a stiff brush or a towel.

45°

35°

6.Install again the inlet hose. Make sure that the couplings are tight to prevent leakages.

7.Open the water tap.

EMERGENCY DRAIN

Because of a malfunction, the appliance cannot drain the water.

If this occurs, do steps (1) through (6) of 'To clean the drain pump'.

If necessary, clean the pump.

Put the drainage duct back and close the drain pump flap.

Page 25
Image 25
AEG L 75270 FL, L 75670 FL, L 75470 FL user manual Inlet Hose Filter, Valve Filter, Emergency Drain