that the steam exhaust is unobstructed. Thus, if a permanent hose installed to an external wall or ceiling, it must be ensured an exhaust capacity of mini- mum 150 m3/h. If the dryer is installed adjacent to kitchen units, make sure that the vent hose is not squashed. If the hose is not fully squashed, drying efficiency will be decreased , resulting in longer drying times and higher ener- gy consumption. If the hose is fully squashed, the automatic cut-outs with which the appliance is fitted can oper- ate. When operating the tumble dryer, the room temperature must not be low- er than +5°C and higher than +35°C, as it can affect the performance of the ap- pliance.

THE LOAD DOOR REVERSAL

WARNING!

Before changing the door stop, disconnect the mains plug.

1.Open load door.

2.Unscrew hinge A from the front of the appliance and remove the load door.

3.Remove cover plates B. To do this, put a thin screwdriver into the slots as shown in the illustration, push down lightly and remove the cover plates.

 

ENGLISH

23

A

B

 

 

C

 

A

B

 

4.Use an applicable tool and apply pressure to unlock part C, remove and turn it through 180°, then put on the other side.

CAUTION!

There is a small spring below locking block C. To put all parts together correctly, look at the il- lustrations: