A

B

C

D

A)green and yellow - ground — earth (E)

B)brown - live (L)

C)cord clamp

D)blue - neutral (N)

The green and yellow coloured wire must be connected to the terminal with E mark or the ground mark or the green and yellow coloured terminal. The blue coloured wire must be con- nected to the terminal N or black col- oured .

ENGLISH 25

The brown coloured wire must be con- nected to the terminal L or red col- oured .

The wires of the cable must be no cut or stray strands of wire present and the cable clamp must be secure over the outer sheath.

Permanent connection

The necessary condition of permanent connection is to install a double-pole isolating switch directly on the supply terminals.

The type of switch must be correct for the necessary load and must align with applicable electrical requirements.

The switch must not break the yellow and green coloured ground wire.