CONTROL TYPES

 

 Voltage control U

rms

Voltage control U

2

rms

 = default setting

Current control I

rms

Current control I

2

rms

Power control P

Without control

PRECISION

 

 U-control: Better than ± 0.5% and ± 1 digit with reference to

the end value.

LIMITATIONS

 

 Voltage limitation U

rms

Current limitaion I

rms

 = default setting

Effective power limitation P

 Peak current limitation, MOSI operation

 

 

Upon reaching one of these limits, the LED ”Limit“ on the 

front panel of Thyro-P is on and the relay K2 is activated.

(terminal strip X2, terminals 10/11/12) 

Relay K1, K2, K3 

Contact load:

 

AC max:  

250V/6A (1500VA)

 

AC min:  

>10VA;

 

DC max:  

300V/0.25A (62.5W)

 

DC min :  

5V/20mA

 

contactor material: AgCdO

WITH UL APPLICATIONS

         

AC max: 

250V/4A

AMBIENT TEMPERATURE 

 

 35°C external cooling (F models)

45°C self air cooling

At higher temperatures it is possible to operate with reduced 

type current: 

COOLANT 

I/I

RATED CURRENT

 

TEMPERATURE 

FORCED COOLING 

SELF COOLING 

[°C]

(VENTILATOR 

TYPES)

 

    

-10 bis 25 

1.10 

1.10 

      

30 

1.05 

1.10 

      

35 

1.00 

1.10 

      

40 

0.96 

1.05 

     

45 

0.91 

1.00 

      

50 

0.87 

0.95 

      

55 

0.81 

0.88 

      

WITH UL APPLICATIONS UP TO +40°C

I/I

Rating

1.2

1.1

1.0

0.9

0.8

0.7

0.6

20

25

30

35

40

45

50

55

60

65

Coolant temperature

Self cooling

Forced cooling

Page 68