Aga Ranges GCB installation instructions Models GE and GEB Balanced flue

Models: GE GCB GC GEB

1 8
Download 8 pages 26.73 Kb
Page 3
Image 3
Models GE and GEB Balanced flue

V = VENT PIPE

S = FLUE PIPE

A B C D E F G H J K L M N P Q R S T U V

mm 1487 889

851

679

41

1330 756 1125

39

3

698

632

591

51

67

116

770

484

328

828

Models GE and GEB Balanced flue

NATURAL G20

MAXIMUM HEAT INPUT

Thermostat Bypass

Main Burner Injector

Pilot Injector

Inlet Pressure G20

PROPANE G31

MAXIMUM HEAT INPUT

Thermostat Bypass

Main Burner Injector

Pilot Injector

Inlet Pressure

Burner Pressure

GE

GEB

5kW

5.8kW

100 or 120

120 or 140

285

330

N35

N35

20mbar

20mbar

5kW (357g/h)

5.8kW (414g/h)

60 or 80

80 or 100

180

200

L23

L23

37mbar

37mbar

28mbar

32mbar

 

 

For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance.