Module Installation
Note | A fully loaded mainframe can weigh over 36 kg (80 lbs). Install the mainframe into the rack before |
| installing the modules into the mainframe. |
|
|
All modules install through the front of the mainframe. Installation (and removal) can be accomplished even when the mainframe is
■Use a
■Extend the pull tab from the module so that the serial number is visible.
■Slide the module into the slot until it is fully inserted in the mainframe.
■Push the pull tab into the front of the module. The slot number should be visible below the pull tab.
Note | If the module is not fully inserted in the mainframe, the pull tab will not retract into the module. |
■Install filler panels in the front of any unused mainframe slots.
■Install the module connectors on the back of the mainframe.
Note | Instructions for wiring and installing module connectors are included with each module. | ||
|
|
|
|
Figure 2-5. Module Pull Tab
Module Removal
All modules are removed through the front of the mainframe. Modules may be removed even when the mainframe is turned on.
18Installation