[Exchange Number Setting]
When interconnecting the exchanges using the
Exchange No. setting
CN6
1 8
SW1
Initial status: Exchange No. 1
1 2 3 4 5 6 7 8
ON
Exchange No. | 1 | 2 | 3 | 4 | 5 – 8 |
1 | OFF | OFF | OFF | OFF | OFF |
2 | ON | OFF | OFF | OFF | OFF |
3 | OFF | ON | OFF | OFF | OFF |
4 | ON | ON | OFF | OFF | OFF |
5 | OFF | OFF | ON | OFF | OFF |
6 | ON | OFF | ON | OFF | OFF |
7 | OFF | ON | ON | OFF | OFF |
8 | ON | ON | ON | OFF | OFF |
9 | OFF | OFF | OFF | ON | OFF |
10 | ON | OFF | OFF | ON | OFF |
11 | OFF | ON | OFF | ON | OFF |
12 | ON | ON | OFF | ON | OFF |
13 | OFF | OFF | ON | ON | OFF |
14 | ON | OFF | ON | ON | OFF |
15 | OFF | ON | ON | ON | OFF |
16 | ON | ON | ON | ON | OFF |
38