7 SETTING UP

OU-100

[3]

[2][8]

MU-100

[5]

[3]

[4]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[6] [8] [7] [1]

Setting upEnglish

First, check that all the installation and wiring work has been completed, that all switches are off, and that all control knobs have been turned to the counterclockwise position.

[1]Turn on the power supply adapter and turn on the POWER switch of the main unit.

[2]Turn on the TALK switch of the operation unit so that communication is possible.

[3]Adjust the receive volume.

Have someone stand and talk in the position on the customer side where the customer would stand, and turn the receive volume knob clockwise to adjust to a suitable volume.

Do not set the volume too high as it could cause problems such

as feedback or detection by the transmit VOX circuit.

Perform while the VOL switch of the operation unit is in the HI position.

[4]Adjust the receive volume in the standby mode. Adjust the volume if necessary.

Have someone stand and talk in the position on the customer side where the customer would stand, and turn the standby volume knob clockwise to adjust to a volume suitable for the standby mode. The volume at the maximum clockwise position is one half of the volume when it is on. There is no sound at the initial counterclockwise position.

When a suitable volume has been reached, turn the TALK switch on and off to check the difference in volume during communication and during standby.

Test while the VOL switch of the operation unit is in the HI position.

[5] Adjust the sensitivity of the VOX circuit.

With the equipment arranged as it would be during use, have someone talk from the operator position. Adjust the VOX sensitivity knob by turning it clockwise so that it responds to the voice and the green LED illuminates. Adjust so that it illuminates when voice transmission starts and goes out when transmission ends.

When stable and the LED is flashing,the minimum knob position is the most suitable. Adjustment is easier if the transmitted sound is checked on the customer side at the same time. It should be noted that sound from the customer side is blocked while the LED is illuminated.

Start by turning the VOX sensitivity knob and transmit volume knob a little clockwise so that the transmitted sound can be heard on the customer side.

[6] Adjust the transmit volume.

Have someone talk from the operator position, and turn the transmit volume knob clockwise to adjust to a suitable volume for the customer side.

Do not set the volume too high as it could cause problems such as feedback.

Adjust the sensitivity of the VOX circuit again if necessary.

Test while the VOL switch of the operation unit is in the HI position.

[7] Adjust the noise canceling control knob.

This function reduces the noise received from around and behind customer. Adjust as necessary. Have someone make a noise that you wish to reduce, and turn the noise canceling control knob clockwise or counterclockwise. Set at a level where the background noise is reduced.

Next, have someone speak from the customer position and check that the volume of the received voice is not affected. Give priority to setting the optimum volume for the voice of the customer. This function is designed to reduce the volume of the background noise, not to eliminate it completely.

If there are no problems with the control position set at the time of shipment (minimum position,turned fully counterclockwise), then adjustment is unnecessary. Adjustment is easier if the headset is used (use speaker side only). Even if the gooseneck microphone and built-in speaker are used with the operation unit, it is recommended that the headset be temporarily connected to perform the adjustment.

[8] Adjust the paging volume.

Have someone talk from the operator position while pushing the PAGE button. Turn the PAGE volume knob clockwise to adjust until a suitable volume is heard from the paging speaker.

Adjust while giving priority to one of the transmit, receive or standby modes of the paging broadcast.

1. Adjustment is only necessary in a system where a paging speaker has been installed.

2. Test while the VOL switch of the operation unit is in the HI position.

- 17 -

Page 17
Image 17
Aiphone IAX-100, Iai-100, IME-100, IME-150, ISE-100, IMU-100 operation manual Setting UP, Setting upEnglish

IME-150, ISE-100, IAX-100, IME-100, IMU-100 specifications

Aiphone, a leading manufacturer of intercom and security communication systems, has developed a range of products designed for different needs and environments. Among their notable offerings are the IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models. Each device comes with unique features, advanced technologies, and specific characteristics suited for various applications.

The Aiphone IAI-100 serves as a powerful intercom system that is ideal for businesses and residential settings. It features a high-resolution display that allows for clear video communication. The IAI-100 utilizes advanced networking technologies, such as IP connectivity, enabling seamless integration into existing networks. With its user-friendly interface, users can easily navigate through functions, making communication efficient. Additionally, its robust security features ensure that conversations are private and protected from unauthorized access.

The IME-100 model is designed for enhanced communication in environments requiring reliability and durability. It incorporates a weather-resistant design, making it suitable for outdoor installations. The IME-100 also supports two-way audio and video communication, providing users with a comprehensive solution for monitoring entry points. Its advanced motion detection technology alerts users to any movement, ensuring proactive security measures.

The IMU-100 offers a versatile solution for both audio and video intercom needs. This unit stands out with its ability to connect multiple devices, allowing for the management of several communication channels simultaneously. Its integration with mobile applications enables users to access their intercom system remotely, offering convenience and control. The IMU-100 also supports high-definition video, ensuring clear visuals for identification and communication purposes.

The IAX-100 model is focused on integrating access control with intercom functionalities. This unit allows users to grant or deny access to visitors through a single interface. It features a built-in access control panel and is compatible with various locking mechanisms, making it a comprehensive solution for commercial buildings. The IAX-100 also provides detailed logging of entry attempts, enhancing security oversight.

Lastly, the ISE-100 is designed specifically for education and institutional applications. It features an easy-to-use interface tailored to the needs of school environments, supporting quick communication between teachers, staff, and administration. The ISE-100 also has features such as emergency notification systems and integration with classroom technology, ensuring safety and communication efficiency.

In summary, Aiphone's IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models are expertly crafted to meet varying communication and security needs across different settings. Each device emphasizes innovative technologies, user-friendly interfaces, and robust security features, making them valuable tools for enhancing connectivity and safety.