Aiphone JBW-BA Wiring, Cablage, Verdrahtung, NPNon-polarized PPolarized, NPNon-polarisé PPolarisé

Models: JBW-BA

1 8
Download 8 pages 26.31 Kb
Page 5
Image 5
WIRING

WIRING

 

 

 

CABLAGE

 

 

 

VERDRAHTUNG

 

 

4BEDRADINGCABLEADO

 

 

 

4-1

 

 

 

1

 

 

[2]

[1]

JBW-BA

 

 

 

2

 

2

 

 

2

 

 

2

[3] PS

 

PS

 

 

[2]

[1]

JBW-BA

 

 

 

2

 

2

 

 

 

2

[4]

 

 

PS

 

 

 

[1]

A1 A2

2

NP

A1 A2

Wiring

English

1.Independent power supply

2.Shared power supply

[1]Color video door station

[2]Color room master station (JA, JB, JF, KC series) CABLAGE Cannot be used for the KB series.

[3]Independent power supply for long distance adapter. Use the same model power supply for the long distance adapter as is used for the color room master station. First, plug in the power supply of the long distance adapter, then plug in the power supply of the master station.

[4]Shared power supply for the room master station and long distance adapter

VERDRAHTUNG When supplying power from the power supply adapter of the color room master station, be sure to observe the restrictions concerning the master station power supply and do not exceed the capacity.

NP:Non-polarized P:Polarized

Câblage

Français

1.Bloc d'alimentation indépendant

2.Bloc d'alimentation commun [1] Portier vidéo couleur

[2] Poste maître intérieur couleur (série JA, JB, JF, KC)

Ne peut pas être utilisé pour la série KB.

[3]

Bloc d'alimentation indépendant pour adaptateur longue

 

distance. Utiliser le même modèle de bloc d'alimentation pour

 

l'adaptateur longue distance que celui utilisé pour le poste

 

maître intérieur couleur. Brancher d'abord le bloc

 

d'alimentation de l'adaptateur longue distance, puis celui du

 

poste maître.

[4]

Bloc d'alimentation commun du poste maître intérieur et

NP:Non-polarized P:Polarized N29

Use THE SAME VOLTAGE power supply as Master station's.

DC24V or 18V

+ -

+

[3] [4]

+

2

 

 

 

 

 

 

PS

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

A1 A2 to Door station

to Master station

JBW-BA

(Observe polarity)

 

 

B1 B2

 

B1

B2

 

2

P

adaptateur longue distance

NP:Non-polarisé P:Polarisé Lorsque l'alimentation provient de l'adaptateur du bloc d'alimentation du poste maître intérieur,veiller à observer les restrictions concernant le bloc d'alimentation du poste maître et à ne pas excéder la capacité.

NP:Non-polarisé P:Polarisé

Verkabelung

Deutsch

1.Separate Spannungsversorgung

2.Gemeinsame Spannungsversorgung [1] Farb-Videotürsprechstelle

[2] Farb-Hauptmonitorsprechstelle (Serie JA, JB, JF, KC)

 

 

 

 

 

A1 A2

 

 

 

 

 

[2]

 

 

 

 

 

 

 

[1]

[2]

 

 

[3] [4]

 

 

JB-DA

JB-2MED

 

 

 

 

 

JB-DV

 

 

 

 

 

JB-2MD

 

 

PS-1820, PS-1820UL,

 

JB-DVF

 

 

 

 

 

PS

:PS-1820S, PS-1820DIN,

DC 18 V

JF-DA

 

 

JF-1MD

 

 

PS-1810DIN

 

 

JF-DV

 

 

 

 

JF-2MED

 

 

 

 

 

JF-DVF

 

 

 

 

 

 

 

 

 

 

 

JA-DAC

JA-2MECD

 

 

PS-2420

 

 

JA-DGC

JA-2MCD

 

 

 

 

 

 

PS-2420UL

 

 

 

KC-1MRD

 

 

 

 

 

 

 

:PS-2420S

 

DC 24 V

 

 

PS

 

 

+ (KC-32EU)

 

 

KC-DAR

 

 

PS-2420DIN

 

 

KC-1GRD

 

 

 

 

 

 

PS-2410DIN

 

 

 

+ (KC-32EU)

 

 

 

 

 

 

 

 

 

 

Kann nicht für Serie KB verwendet werden.

[3]JBW-BA mit eigener Spannungsversorgung. Für JBW-BAden gleichen Typ Netzgerät verwenden, wie für die Hauptmonitorsprechstelle. Erst das Netzgerät des JBW-BA, dann das der Hauptstelle an das Netz anschließen.

[4]Gemeinsames Netzgerät für JBW &Hauptmonitor

NP:keine Polarität P:Polarität beachten Bei Versorgung von einem gemeinsamen Netzgerät, bitte Vorgaben der Monitorstelle beachten und sicherstellen, dass das Netzgerät nicht überlastet wird.

NP:keine Polarität P:Polarität beachten

- 5 -

Page 5
Image 5
Aiphone JBW-BA installation manual Wiring, Cablage, Verdrahtung, NPNon-polarized PPolarized, NPNon-polarisé PPolarisé