Aiphone LE-SS-1G warranty Instructions, Installation, Wiring Diagrams

Models: LE-SS-1G

1 2
Download 2 pages 17.04 Kb
Page 1
Image 1
Vandal and Weather Resistant 1-Gang Sub Station

Vandal and Weather Resistant 1-Gang Sub Station

- INSTRUCTIONS -

The LE-SS-1G is a 1-gang stainless steel vandal proof and weather resistant sub station designed for use with the LEM, LEF, LAF/LDF-C, AP-M, and MP-S systems. This unit is constructed with 12 gauge stainless steel and can be flush mounted into a 1-gang box, or surface mounted with the SBX-1G. Each unit includes tamper proof screws and a tool for installation.

INSTALLATION:

1. For flush mounting, install sub station in standard 1-gang electrical box with min. 2-1/2" depth.

2. For surface mounting, install sub station in the SBX-1G surface mount enclosure.

3. IMPORTANT! This unit is designed for use in normal weather conditions, and is made to allow for drainage and evaporation of moisture that naturally gets into it. Do not apply caulking or silicone sealant around the unit when installing, and do not use weather stripping around the perimeter of the box when mounting. If sealing the unit is required, the bottom must remain unsealed. Sealing the unit will prevent or inhibit moisture from dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time. Warranty does not cover damage caused by sealing the unit.

1-1516

LE-SS-1G

Back View

WIRING DIAGRAMS:

LEM SYSTEM:

2-⅞” 3-¼”

LEM Master

2 conductor

LE-SS-1G

shielded wire

 

 

 

 

1

Power

E

Source*

 

 

 

+

 

 

+

 

 

-

 

 

 

-

 

 

 

*LEM-1 or LEM-3: Use SKK-620 (6V DC)

LEM-1DL: Use PT-1210N (or any source providing 12-16V AC or 12-24V DC)

Red

Blk* Jumper Blue & Black

Blu wires together.

 

 

 

 

 

 

WIRE COLOR CODE DEFINITIONS:

 

 

 

 

 

 

Red: + side of speaker & call switch, connect to # of master

 

 

 

 

 

 

Black: Common communication, connect to E of master

LEF, LAF-C, or LDF-C SYSTEM:

 

Blue: - side of call switch

 

 

LEF, LAF/LDF-C

LE-SS-1G

 

 

 

 

 

Master Station*

 

 

 

 

 

 

1

 

 

Red

LE-SS-1G

 

 

 

 

 

 

 

 

2

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

~

 

 

3 conductor

 

 

 

 

PS-1225UL

10

 

 

shielded wire

 

 

 

* In a single master LEF system

 

 

 

 

 

 

 

 

 

E

 

Blk*

 

Blk*

only, 2 conductors homerun can

 

 

 

 

+

 

+

 

 

 

 

 

 

be used with the BLK and BLU

-

 

-

 

 

Blu

 

Blu

wires tied together and "E" and "-"

 

 

 

 

 

 

 

 

 

 

jumpered at the master station.

Page 1

Page 1
Image 1
Aiphone LE-SS-1G warranty Instructions, Installation, Wiring Diagrams, Vandal and Weather Resistant 1-Gang Sub Station