Special
Order
Products
NDR-RS
NDR Lamp Memory Master Station with External Control Capability for Rescue Assitance
- INSTRUCTIONS -
The
WIRING DIAGRAM: SYSTEM USED FOR CCTV CAMERA CALL-UP
NDR-20RS
1
2
3
~
20
E
S
H
External
Terminal Block
|
| ||
Red | Red | Red |
|
Green | Green | Green | Leave green |
jumper | jumper | jumper | jumper intact |
|
|
| |
Blu | Blu | Blu |
|
Pur | Pur | Pur |
|
Blk | Blk | Blk |
|
Yel | Yel | Yel |
|
Org | Org | Org |
|
1
2
3
~
20 L
|
|
|
|
|
|
| BLK |
|
| ||
|
|
|
|
|
|
| YEL | Closure for Station #1 | |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| #3 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| BLK |
|
|
|
|
|
| ||
|
|
| YEL | Closure for Station #2 |
| ||||||
|
|
|
|
|
| ||||||
|
|
|
|
| #2 |
|
|
| Normally Open contacts remain | ||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
| BLK |
|
|
|
|
|
|
| |||
| YEL |
| Closure for Station #3 | ||||||||
|
| #1 |
|
|
|
|
|
|
| closed as long as master has sub | |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
station selected.
+ | + | Terminal Block | DUAL FUNCTIONS FROM EACH CHANNEL: | ||||||
|
| ||||||||
- | - |
| 1 |
|
|
|
|
| |
| Equipment for each station that requires | BLK | YEL |
| Momentary closure #1 | ||||
| both a constant closure and momentary |
| #1 |
| |||||
|
|
|
|
|
| ||||
| closure when a channel is selected: |
|
|
|
|
|
|
|
|
| 2 |
|
| BLK | YEL |
| Constant closure #1 | ||
| 1 Diode (1N4001) |
| L | #2 |
| ||||
|
|
|
|
|
|
| |||
Individual Components for System: |
|
|
|
|
|
|
|
| |
| 2 |
|
|
|
| ||||
|
|
|
| Momentary | |||||
|
|
|
| BLK | #1 | YEL | |||
|
|
| closure #2 | ||||||
|
|
|
|
| |||||
|
|
| Constant | ||||||
Relay for selective output (1 per station requiring external contact) |
|
|
|
| BLK | ||||
| H |
|
| #2 | YEL | ||||
|
|
| closure #2 | ||||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||
24V DC, 2A Power Supply for |
|
|
|
|
|
|
|
| |
|
|
|
|
| |||||
|
|
|
|
|
| ||||
IMPORTANT: |
| + | Positive 24V DC |
|
|
|
| ||
| - | Negative |
|
|
|
|
| ||
1. |
|
|
|
|
|
| |||
| 1~40 | Station number |
|
|
|
|
| ||
to isolate AC voltage from the intercom circuit. |
|
|
|
|
|
| |||
| E | Common communication |
|
|
| ||||
2. Extra contact connections and L are on separate |
|
|
|
| |||||
| S | Sends "call placed" tone to sub |
|
|
| ||||
terminal block. |
|
|
|
| |||||
| H | Resets call signals at sub when RESET |
| ||||||
|
|
| Pg. 1 | ||||||
|
|
|
| button is pressed. |
|
|
| ||
|
|
|
|
|
|
|
|