MODEL /MODELO/ MODÉLE 4CH68G/9500G

OPERATING INSTRUCTIONS & PARTS MANUAL

20" DELUXE PIVOT FAN

MODEL 4CH68G/9500G

This Fan is not intended to be used in

commercial, industrial or agricultural settings.

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT

DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

 

 

 

 

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

DESCRIPTION

 

 

 

 

 

 

WARNING: USE OF A THREE-PRONG TO TWO-PRONG

The Air King 20" (50.8 cm) Deluxe Pivot Fan features 3 speed whis-

ADAPTER IS NOT RECOMMENDED. IMPROPER

CONNECTION MAY CREATE THE RISK OF ELECTRO-

per-quiet operation, a 5-paddle fan blade, and 120° adjustable tilt.

CUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED

The fan has a permanently lubricated motor with a 6 ft. (1.8 m) 18/3

IN CANADA.

cord set.

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: THIS PLUG IS A SAFETY FEATURE. TO

SPECIFICATIONS

 

 

 

 

 

 

 

 

REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND

Motor .................................120V, 60 Hz

 

 

PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR

Blade diameter ...................20" ( 50.8 cm)

 

 

 

 

OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF

Speeds ...............................3

 

 

 

 

 

 

 

 

THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE

Control ................................Rotary Switch

 

 

Air flow distribution .............120°

 

 

 

 

DUE TO THE SAFETY DEVICE INCORPORATED IN THIS

Approvals............................UL Listed. Close mesh fan guard

PLUG. CONTACT YOUR GRAINGER DISTRIBUTOR.

 

 

 

 

meets OSHA requirements.

8. Where possible, avoid the use of extension cords. If they must

 

 

MODEL

 

4CH68G/9500G

 

 

be used, minimize the risk of overheating by ensuring that they

 

 

SPEED

 

HIGH

 

MED

 

LOW

 

are UL listed. Never use a single extension cord to operate more

 

 

CFM

 

2470

 

2055

 

1570

 

than one Fan.

 

 

 

 

 

 

9. Do not operate any Fan with a damaged cord or plug or after the

 

 

M3/s

 

1.17

 

0.97

 

0.74

 

 

 

RPM

 

1137

 

1018

 

777

 

Fan malfunctions, has been dropped or damaged in any manner.

 

 

 

 

 

 

Return Fan to authorized service facility for examination, electrical

 

 

Amps

 

1.05

 

0.82

 

0.62

 

 

 

 

 

 

 

or mechanical adjustment or repair.

 

 

Watts

 

129

 

106

 

79

 

 

 

 

 

 

 

10.Do not insert or allow fingers or foreign objects to enter any

 

 

 

 

 

 

 

 

 

 

 

 

dB A

 

64

 

60

 

52

 

 

 

 

 

 

 

ventilation or exhaust opening as it may cause an electric shock

 

 

 

 

 

 

 

 

 

 

GENERAL SAFETY INFORMATION

or fire, or damage the Fan. Do not block or tamper with the Fan

in any manner while it is in operation.

When using electrical appliances, basic

11.Always place the Fan on a stable, flat, level surface when operating,

precautions should always be followed to

to avoid the chance of the Fan overturning. Locate the Power Cord

reduce the risk of fire, electric shock and injury

so the Fan or other objects are not resting on it. Do not run Power

to person, including the following:

Cord under carpeting. Do not cover Power Cord with throw rugs,

1. Read all instructions before using Fan.

 

 

runners, or the like. Arrange Power Cord away from room traffic

 

 

and where it will not be tripped over.

2.

Make certain that the power source conforms to the electrical

 

requirements of the Fan.

 

 

 

 

12.This Fan is not intended for use in wet or damp locations. Never

3.

Use this Fan only as described in this manual. Any other use

locate a Fan where it may fall into a bathtub or other water container.

 

not recommended by the manufacturer may cause fire, electrical

13. Do not use Fan outdoors.

 

shock, or injury to persons.

 

 

 

 

14.This Fan is not suitable for use in agricultural facilities including

4. Unplug power cord before installing, servicing, or moving the Fan.

areas where livestock, poultry or other animals are confined.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS

Please refer to National Electric Code (NEC) Article 547-7 (2002),

THE SOLE MEANS OF DISCONNECTING POWER WHEN

or applicable state or local codes or standards relating to electrical

INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE

POWER CORD.

 

 

 

 

 

 

requirements for Agricultural Buildings. THIS FAN DOES NOT

5. This Fan must NOT be used in potentially dangerous

MEET THE REQUIRMENTS OF NEC ARTICLE 547-7 (2002).

 

locations such as flammable, explosive, chemical-laden

15.This Fan is not suitable for use in hazardous locations. Please refer to

 

or wet atmospheres.

 

 

 

 

 

 

 

 

 

National Electric Code (NEC) Article 500 or applicable state or local

6.

DO NOT use Fan in or near a window. Rain may create an

codes or standards relating to electrical requirements for Hazardous

 

electrical hazard.

 

 

 

 

 

 

 

 

 

 

 

 

 

locations. THIS FAN DOES NOT MEET THE REQUIRMENTS OF

7. The power cord is equipped with a three-prong grounded plug

NEC ARTICLES 500 (2002)

 

that must be inserted into a matching receptacle. Under no

 

circumstances must the grounding prong be cut off the plug.

WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK

 

Where a two-prong wall receptacle is encountered, it must be

– DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED

 

replaced with a properly grounded three-prong receptacle installed

CONTROL DEVICES.

 

in accordance with the National Electrical Code (NEC) and all

SAVE THESE

 

applicable local codes and ordinances. This work must be done

 

only by a qualified electrician, using copper wire only.

 

 

 

 

 

 

 

 

 

 

INSTRUCTIONS

Rev. P 6/07

8

2084007

Rev. P 6/07

1

2084007

Page 1
Image 1
Air King 4CH68G, 9500G specifications Description, Specifications, General Safety Information