DESCRIPTION
The Air King® 20" (50.8 cm) Box Fan features 3-speed rotary knob operation,roundedcorners. The20"(50.8cm)5-paddlebladeisdriven by a permanent lubricated motor with a 6 foot (1.8 m) 18/3 cordset.
SPECIFICATIONS
Motor | 120V, 60 Hz | | |
Blade diameter | 20" ( 50.8 cm) | | |
Speeds | 3 | | | | | |
Control | Rotary Knob | | |
Approvals | ETL Listed. Close mesh fan guard |
| | meets OSHA requirements. |
| MODEL | | 4CH71F/9723F | | |
| SPEED | HIGH | | MED | | LOW | |
| CFM | 2163 | | 1900 | | 1463 | |
| | | | | | | |
| M3/s | 1.02 | | 0.90 | | 0.69 | |
| | | | | | | |
| RPM | 1220 | | 1075 | | 855 | |
| | | | | | | |
| Amps | 0.94 | | 0.72 | | 0.56 | |
| | | | | | | |
| Watts | 105 | | 87 | | 65 | |
| | | | | | | |
| dB A | 60 | | 55 | | 51 | |
| | | | | | | |
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, elec- tric shock and injury to person, including the following:
1.Read all instructions before using Fan.
2.Make certain that the room is equipped with a working smoke detector.
3.Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.
4.Unplug power cord before installing, servicing, or moving the
Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALL- ING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
5.This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres.
6.DO NOT use Fan in or near a window. Rain may create an electrical hazard.
7.The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circumstances must the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using cop-
per wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CRE- ATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: This plug is a safety feature. To reduce the risk of fire, electric shock and personal injury, do not remove, replace, repair or tamper with the originally supplied plug. If the Fan does not function properly, it may be due to the safety device incorporated in this plug. CONTACT YOUR GRAINGER DISTRIBUTOR.
8.Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.
9.Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner. Return Fan to authorized service facility for examination, electrical or mechanical adjustment or repair.
10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.
13. Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS FAN
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).
15.This Fan is not suitable for use in hazardous locations. Please refertoNationalElectricCode(NEC)Article500orapplicablestate or local codes or standards relating to electrical requirements for Hazardous locations. THIS FAN DOES NOT MEET THE
REQUIREMENTS OF NEC ARTICLE 500 (2008).
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.
SAVE THESE INSTRUCTIONS
3
4
5
116
8
10
9
7
LISTE DES PIECES DE REMPLACEMENT
No | No | | | | |
de réf | de pièce | Description | Qte. | |
| | | | | |
1 | 2091119 | Vis #6 x 0,9 cm PPH type AB ZP | | 12 | |
| | | | | |
2 | 2018001 | Grille arrière | | 1 | |
| | | | | |
3 | 2011405 | Poignée | | 1 | |
4 | 2011402 | Bouton | | 1 | |
| | | | | 1 |
5 | 2061713 | Châssis du ventilateur | | 1 |
6 | 02050031WFPB | Cordon d'alimentation uniquement | 1 | |
7 | 02031246S | Moteur avec interrupteur | | 1 | |
8 | 2011278 | Lame | | 1 | |
9 | 2018000A | Grille avant | | 1 | |
| | | | | |
10 | 2091211 | Vis #10 x 1,3 cm PPH Type A | | 4 | |
11 | 2091118 | Vis #6 x 0,9 cm PPH Type AB Grn | 1 | |
OPERATION
1.Brancher le ventilateur dans une prise de courant standard à 120 Vca.
2.Régler la vitesse désirée à l'aide de l'interrupteur rotatif.
MAINTENANCE
AVERTISSEMENT: TOUJOURS DEBRANCHER LE CORDON D'ALIMENTATION AVANT D'EFFECTUER UN SERVICE.
NETTOYAGE: Utiliser un chiffon doux et une solution à base de détergent doux comme du liquide pour la vaisselle.
NE JAMAIS IMMERGER DES PIECES ELECTRIQUES DANS L'EAU.
AVERTISSEMENT: Ne pas utiliser d'essence, de benzène, de nettoyeurs forts, etc., qui vont endommager le ventilateur. Sécher complètement toutes les pièces avec un chiffon doux avant de rebrancher l'alimentation.
RANGEMENT: Ranger le ventilateur dans un endroit frais et sec.
LE MOTEUR EST LUBRIFIE EN PERMANENCE.