WALL SWITCH WIRING
1.Unscrew the speed control cover and screw base onto wall.
2.Connect the switch white wire to the black (Hot) supply wire using a listed wire nut. Connect the switch black wire to the black (Hot) lead wire from the fan using a listed wire nut. (Figure 7)
White Supply (Neutral)
Black lead | Black |
Supply | |
from fan | (Hot) |
(Hot) |
|
| Wall |
| Switch |
Figure 7
3.Replace the front cover of the switch control box with the supplied screws and tighten.
ATTACHING FAN BLADES
1.Insert one screw through the lockewasher and into the motor hub. Do not tighten fully at this time. (Figure 8)
2.Install the second screw in the same manner, then tighten both screws fully.
3.Repeat steps 1 and 2 for the 2 remaining blades.
| Screw & | Blade |
Figure 8 | lockwasher |
|
|
|
MAINTENANCE
Periodic cleaning of your ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to the finish. Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock or fire.
WARRANTY
The ceiling fan you have purchased is warranted by the manufacturer for one year from the date of purchase against defects in workmanship and/or materials. The motor is warranted for ten years. This warranty means that only the parts that prove to be defective during the period of warranty will be either repaired or replaced at our option. The right is reserved by the manufacturer to replace the whole product in lieu thereof. Should repair become necessary during the warranty period, write to: AIR
KING c/o LASKO PRODUCTS, INC., Appliance Service Department, 820 Lincoln Ave., West Chester, PA 19380. Describe the problem you are having. DO NOT
SEND FAN!
This warranty does not apply if the damage occurs because of accident, improper handling, installation or operation, shipping damage, abuse, misuse or unauthorized repairs made or attempted. ALL WARRANTIES, EXPRESSED OR IMPLIED LAST FOR ONE YEAR FROM DATE OF ORIGINAL PURCHASE, EXCEPT FOR THE MOTOR. THIS WARRANTY DOES NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER. Some states do not allow limitations on how long any implied warranty lasts, or the exclusion or limitations of incidental or consequential damages, so that the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights that vary from state to state.
FOR REPLACEMENT PARTS: Please call
FOR QUESTIONS OR COMMENTS ABOUT YOUR CEILING FAN: Please call
New 7/00
INSTRUCTION MANUAL
Models: 9848, 9856 & 9860
INDUSTRIAL CEILING FAN
READ AND SAVE THESE INSTRUCTIONS
1.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
2.All wiring must satisfy National and Local electrical codes. The ceiling fan must be grounded as a precaution against possible electrical shock.
3.The electrical outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds.
4.WARNING: To reduce the risk of fire, electrical shock and/or personal injury:
a)Be sure electricity is turned off at the main fuse box before wiring, cleaning or servicing.
b)Fan should not be mounted in areas where it might become wet
RULES FOR SAFE OPERATION
1.Be careful of the fan and moving blades when cleaning, painting or working near fan.
2.Do not put anything into the blades while they are turning.
3.Do not bend the blade brackets when installing the brackets, balancing the blades or cleaning the fan.
4.WARNING: The fan must be hung with at least 7 feet of clearance from floor to blades.