Air King AK100L, AK100FL manual Section, Installation Instructions, Mounting Rail, Collar

Models: AK100FL AK100L

1 12
Download 12 pages 46.09 Kb
Page 2
Image 2
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have:

1 - Grill

1 - Damper Assembly (attached)

4 - Mounting Rails

1 - Instruction/Safety Sheet

2.Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The

fan mounts between 16" or 24" on center joists using the 4 provided mounting rails.

3.Select the most convenient electrical knockout and remove using a straight-blade screw driver (Figure 1).

SECTION 2

Figure 1

New Construction

 

1.Install the side mounting rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the mounting rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 2).

Housing

 

 

Joist

Figure 2

Mounting Rail

 

SECTION 3

Existing Construction

1.Set housing in position between the joist and trace an outline onto the ceiling material (Figure 3). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the side mounting rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the mounting rails to the joists (Figure 2).

Joist

Figure 3

SECTION 4

Ducting

CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES.

1.Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.

Ducting

Duct

Collar

Figure 4

SECTION 5

Wiring

CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

NOTE: This unit includes a side access panel for wiring that does not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective.

1a. External Wire Compartment: Remove the wire compartment cover screw and place cover in a secure place (Figure 5).

Screw

Wire

Compartment

Cover

Figure 5

210952012 Rev. B 8-06

www.airkinglimited.com

2 of 12

Page 2
Image 2
Air King AK100L, AK100FL manual Section, Installation Instructions, Mounting Rail, Collar