Figure 11
5. Restore power and test your installation.
CAUTION: ALLOW BULBS TO COOL BEFORE REPLACING.
3.Changing the Light Bulb: Disconnect power to the unit. Remove grill by pulling downward on grill and squeezing grill springs together to release from housing (Figure 12).
Flourescent Bulbs: Remove bulbs by gently rocking bulb back and forth while applying outward pressure to release the bulb from the base. Replace with Air King model 13WQ2700 or a compatible 13 watt maximum, two pin, quad tube, instant on (flicker free), compact fluorescent bulb.
Night Light: Unscrew night light bulb from socket and replace with a 4 watt maximum type C7 (candelabra base) night light bulb.
SECTION 7
Use and Care
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT.
1.Cleaning the Grill: Remove grill and use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 Finishing the Installation, to reinstall grill.
2.Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
Figure 12
Troubleshooting Guide
| Trouble |
| Probable Cause |
| Suggested Remedy |
1. | Fan does not operate when the switch is on. | 1a. | A fuse may be blown or a circuit tripped. | 1a. | Replace fuse or reset circuit breaker. |
|
| 1b. | Connector plug from motor is not plugged in. | 1b. | Turn off power to unit. Remove Grill and plug motor into receptacle |
|
|
|
|
| in housing. Restore power to unit. |
|
| 1c. | Wiring is not connected properly. | 1c. | Turn off power to unit. Check that all wires are connected. |
|
| 1d. | Motor has stopped operating. | 1d. | Replace motor. |
|
|
|
|
| |
2. | Fan is operating, but air moves slower than normal. | 2. | Obstruction in the exhaust ducting. | 2. Check for any obstructions in the ducting. The most common are bird nests | |
|
|
|
|
| in the roof cap or wall cap where the fan exhausts to the outside. |
3. | Fan is operating louder than normal. | 3a. | Motor is loose. | 3a. | Turn off power to unit. Remove grill and check that all screws are fully |
|
|
|
|
| tightened. Restore power to unit. |
|
| 3b. | Fan blade is hitting housing of unit. | 3b. | Call your dealer for service. |
|
|
|
|
|
|
210572080 Rev. A | www.airkinglimited.com | 4 of 12 |