Digital Congress Network Installation and Operating Manual Chapter 7 - DCN Installation Accessories

en 7-3

 

 

7.1.3 Cable assemblies and connectors

The following Cable assemblies are available with the DCN system.

LBB 4116/00 Installation cable (100 m (328 ft.) without connectors)

LBB 4116/xx Extension cable assembly (available in various cable lengths)

Extension cable assemblies LBB 4116/xx

These cable assemblies are used to extend the length of the trunk-line cable and to extend the length of cable between a delegate, chairman or interpreter desk.The cable assemblies are ter- minated with moulded 6-pole circular connectors (male and female).

The 6-pole circular connectors male and female include a plug locking facility.To interlock the male and female connectors use cable locking clamps LBB 4117/00.

Installation cable LBB 4116/00

Supplied without connectors the 100 m (328 ft.) installation cable is for use in installations where the normal DCN unit cables and extension cable assemblies are too short.

Cable Connection details:

1

5

2

4

3

6

Ground

FIG 7-5 DCN Cable connection details

Available Extension cables

 

 

 

 

LBB 4116/02

2 m (6.5 ft.)

 

 

 

 

LBB 4116/05

5 m (16.4 ft.)

 

 

 

 

LBB 4116/10

10 m (32.8 ft.)

 

 

 

 

LBB 4116/15

15 m (49.2 ft.)

 

 

 

 

LBB 4116/20

20 m (65.6 ft.)

 

 

 

 

LBB 4116/25

25 m (82 ft.)

 

 

Cable Locking clamp

 

 

LBB 4116/05

 

 

 

 

LBB 4117/00

 

 

Male

BOSCH

 

 

 

 

Male

 

 

 

 

 

 

 

 

 

 

3

 

3

 

Female

 

4

2

2

4

 

 

 

 

 

BOSCH

 

5

1

1

5

 

6

 

6

 

 

 

 

 

 

 

Male

 

Female

 

PIN 1

-

Down-link screen/ground

PIN 2

-

Down-link signal (green)

PIN 3

-

Positive supply (max. 40V) (brown)

PIN 4

-

Up-link-signal (white)

PIN 5

-

Up-link screen/ground

PIN 6

-

Positive supply (max. 40V) (blue)

Custom-made cables

For customising DCN system cable connections, refer to the table below.

DCN Trunk-cable connectors

Hirschmann

Service

 

Type No.

Code No.

 

 

 

Cable-plug (Black) with locking screw (male)

MAS 6100

5322 264 54055

Cable-plug (Black) without locking screw (male)

MAS 60

4822 264 40026

Cable socket with locking screw (female)

MAK 6100

5322 264 10367

 

 

 

Note: MAS 6100 cannot be used in the Trunk-splitter due to the length of cap. Therefore, use a Hirschmann plug without locking (MAS 60).

NOTE: The screening of the DCN cable is connected to the earth tag of the Hirschmann cable plug/socket, and is potentially live.Therefore only use isolated sockets for extension cables, patch panels and floor boxes.

FIG 7-4 LBB 4116/05 Extension cable assembly (5m) (16.4 ft.)