Digital Congress Network Installation and Operating Manual Chapter 13 - Technical Data

en 13-11

 

 

13.6 System limitations

1.

The maximum length of cable (including the 2 m cable attached to the DCN system units) that

 

can be connected to a tap-off outlet of a Central Control Unit LBB 3500/.., Audio Media Interface

 

Unit LBB 3508/00 and Extension Power Supply LBB 4106/00 must not exceed 100 m.

2.

The cable length between the Central Control Unit and the last unit in any system installation

 

must not exceed 250 m.This includes all extension cables used as well as the 2 m long cable

 

attached to each system unit.

13.7 Connection details

13.7.1 Mains cable

The wires in the mains cable are coloured in accordance with the following code:

BlueNeutral

Brown Live Green/yellow Earth/Ground

3.

The maximum number of serial tap-off outlet connections from the Central Control Unit LBB

 

3500/.. to the last tap-off in its chain should not exceed four.

 

Tap-off outlets are available on the Extension Power Supply Unit LBB 4106/00, Audio Media Inter-

 

face Unit LBB 3508/00,Trunk-cable splitter LBB 4114/00, and Tap-off unit LBB 4115/00.

4.

The maximum number of units that can be connected in series, via the trunk outlet loop-through

 

connector, is 60 Units (i.e. units assigned a PCF value of 1) also include, the delegate, chairman

13.7.2 DCN circular connectors

PIN 1

Down-link screen

PIN 2

Down-link signal

PIN 3

< +40 V

PIN 4

Up-link signal

PIN 5

Up-link screen

PIN 6

< +40 V

3

 

 

3

4

2

2

4

5

1

1

5

6

 

 

6

and interpreter desks, Dual Audio Interface Unit LBB 3535/00 and the Multi-purpose Connection

Unit LBB 3540/15 and trunksplitter LBB 4114/00.

13.7.3

Cable connection

 

 

3-pole XLR connector (female)

 

 

PIN 1

Earth

 

 

PIN 2

Signal +

2

1

PIN 3

Signal -

 

 

3

13.7.4Pluggable microphones LBB 3549/xx

5-pole XLR connector (male)

PIN 1

lightring control (active low)

PIN 2

lightring +5V

PIN 3

microphone signal

PIN 4

electrical ground

PIN 5

shield

1

5

2

4

 

3

 

3