Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-4

 

 

Max. number of units connected in series (without the use of extension cables)

The maximum number of units connected in series to a Trunk outlet or Tap-off of a CCU (LBB 3500), Extension Power Supply unit (LBB 4106/00) and Audio Media Interface unit (LBB 3508/00) is:

Table-top units

-50 x Delegate/Chairman discussion units with a PCF value of 1(see Limit 1)

Flush mounted units

-40 x Dual Audio Interface units (see Limit 2),

or 30 x Multi-purpose connection units (see Limit 2), or 50 x Channel selector units (see Limit 1),

or 24 x Delegate/Chairman Concentus units including interpreter desks with a PCF value of 2.5 (see limit 2).

Limit 1: The maximum cable length is 100 m (328 ft.). The length of cable attached to each unit is 2 m (6.5 ft.), therefore a maximum of 50 discussion units (50 x 2 m (6.5 ft.) = 100 m (328 ft.)) can be connected even though the maximum PCF value of 60 has not yet been reached.

Limit 2: The maximum total PCF value that can be connected to one outlet is 60.The Dual Audio Interface has a PCF value of 1.5 (40 x 1.5 = 60) and the Multi-purpose connection unit has a PCF value of 2 (2 x 30 = 60).

System overload

Each outlet socket is protected against short circuit at the power supply lines, and each has a red LED indicator (FIG 10-3)to indicate when the trunk-line has exceeded its maximum PCF value. In an overload situation, when the LED is lit, the system has a built-in delay time of 30 seconds before scanning the system again for a repeat overload situation. If the overload has been corrected the LED goes out. Refer to Chapter 10.2 Power Handling Capacity.

 

Overload LED

 

 

 

also applicable

 

 

for LBB 4106/00

 

Port 1

Rec.

Line

Trunk

 

In

In

 

 

Port 2

Out

Out

115 V -T4A 230 V -T2A

 

 

Symmetrical

 

 

LBB 3500/xx Central Control Unit

 

 

Port 1

Rec.

Line

Trunk

 

 

In

 

In

 

 

 

 

 

 

Out

 

Out

115 V -T4A 230 V -T2A

 

 

 

 

Symmetrical

 

 

 

 

 

 

LBB 4106/00

 

 

 

 

Trunk

Tap-off

 

1st Tap-off

 

11 5V-T 4A 2 30V -T2A

 

LBB 4114/00

In

 

 

 

 

 

 

 

 

1st Tap-off

 

LBB 4114/00

 

 

 

2nd Tap-off

Tap-off

Trunk-line

 

 

 

 

 

 

 

 

3rd Tap-off

LBB 4114/00

 

 

 

 

 

 

 

 

 

 

2nd Tap-off

Tap-off

Trunk-line

 

 

4th Tap-off

LBB 4114/00

 

 

 

 

 

3rd Tap-off

 

 

 

 

5th Tap-off

LBB 4114/00

 

 

 

 

 

4th Tap-off

FIG 10-3 Overload indication

FIG 10-4 Tap-off limitations

Bosch Security Systems 04-2003 3922 988 43318 en

Trunk outlets and Tap-offs

Page 108
Image 108
Bosch Appliances 3922 988 43318 manual Table-top units, Flush mounted units, Overload indication, System overload