Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-2

 

 

10.2

Power Handling Capacity

 

 

 

 

 

 

 

 

To understand the power handling capacity of a system, individual DCN units have been assigned with

LBB 3500/xx Central Control Unit

LBB 3508/00 Audio Media Interface Unit

a Power Consumption Factor (PCF). The PCF therefore has a bearing on the total number of units

 

 

 

 

 

 

 

 

that can be connected to a system.The maximum number of units, quoted for a CCU is based on all

Port 1

Rec.

Line

Trunk

Output 1 Output 2

Output 3 Output 4

Trunk

Tap-off

units having a PCF of 1.This means for example, that a CCU can accommodate 60 units of PCF (valid

 

In

In

 

 

 

 

 

 

Out

Out

115 V -T4A 230 V -T2A

 

 

 

115 V -T4A 230 V -T2A

for each trunk/tap-off output), but can also accommodate 120 units of PCF 0.5. Table No. 10.1 gives

 

 

Symmetrical

 

 

 

 

 

the PCF value rated for each DCN system unit.

PCF =

60 max.

 

PCF =

60 max.

 

 

The length of (extension) cable used also has an influence on the number of units connected to a

 

 

 

 

 

 

 

 

 

 

 

system. Therefore to calculate the PCF value in relation to the length of cable used, a calculation

LBB 3500/05 Central Control Unit

 

 

 

 

graph has been devised (refer to Chapter 10.4 “Calculating the PCF of a system”).

 

 

 

 

Output 1 Output 2

Output 3 Output 4

Trunk

Tap-off

FIG 10-1shows the maximum PCF values that can be connected to a single and all three trunk-

Port 1

In

In

 

 

 

 

115 V -T4A 230 V -T2A

 

 

Rec.

Line

Trunk

 

 

 

 

outlets of the following units:

 

 

 

 

 

 

 

 

Out

Out

115 V -T4A 230 V -T2A

 

 

 

 

1. Central Control Unit LBB 3500/..

 

 

 

Symmetrical

 

 

 

 

 

 

 

PCF = 90 max.

 

2. Audio Media Interface unit LBB 3508/00

 

PCF = 90 max.

 

3. Extension Power Supply Unit LBB 4106/00

 

 

 

 

 

 

 

 

 

 

 

Table 10.1: Power Consumption Factor PCF

 

LBB 3500/15 and LBB 3500/35

 

 

 

Central Control Unit

 

 

 

Type No.

DCN Unit Description

PCF Value

Port 1

Rec.

Line

Trunk

 

 

LBB 3530/xx

Delegate unit (discussion)

1

 

In

In

 

 

 

Port 2

Out

Out

115 V -T4A 230 V -T2A

 

 

LBB 3531/xx

Delegate unit (discussion)

1

 

 

Symmetrical

 

 

 

LBB 3533/xx

Chairman unit (discussion)

1

PCF =

180 max.

 

 

 

LBB 3534/xx

Chairman unit (discussion)

1

 

 

 

 

 

 

 

 

 

LBB 3544/00, LBB 3545/00

Delegate unit (Concentus)

2

 

 

 

 

 

 

LBB 3546/00

Delegate unit (Concentus)

2.5

 

 

LBB 4106 Ext. Power Supply Unit

LBB 4106 Ext. Power Supply Unit

LBB 3547/00

Chairman unit (Concentus)

2.5

 

 

 

 

 

 

LBB 3520/10

Interpreter desk

2.5

 

 

Trunk

Tap-off

Trunk

Tap-off

 

 

 

 

 

 

LBB 3524/xx

Channel selector unit

0.5

 

 

 

11 5V-T 4A 2 30V -T2A

 

11 5V-T 4A 2 30V -T2A

 

 

In

 

In

 

LBB 3526/10

Channel selector unit

0.5

PCF =

60 max.

 

 

 

LBB 3535/00*

Dual audio interface unit

1.5

PCF =

180 max.

 

 

 

 

 

LBB 3540/15

Multi-purpose connection unit

2

 

 

 

 

 

 

LBB 3512/00

Data Distribution Board

1

 

 

 

 

 

 

LBB 4106/00 (D)

Extension Power Supply Unit

0.5

FIG 10-1 Power Handling Capacities

 

 

LBB 3508/00 (D)

Audio Media Interface unit

0.5

 

 

 

 

 

 

 

 

LBB 3423/00

DCN Interface module

0.5

 

 

 

 

 

 

LBB 3510/00

PC network card

1

REMINDER: The Central Control Unit type LBB 3500/05 has a maximum rated PCF

LBB 3513/00

Analog Audio Input/Output Module

1

value of 90 PCF. Central control units type LBB 3500/15 and LBB 3500/35 have a

LBB 4114/00

Trunk-cable Splitter

1

maximum rated PCF value of 180 PCF.

 

 

LBB 4115/00

Tap-Off unit

1

 

 

 

 

 

 

The PCF value of a unit includes its attached 2 m (6.5 ft.) long cable.

 

 

 

 

 

 

 

*The PCF value of these units include the flush-mounted units and/or hand microphones connected to it

Bosch Security Systems 04-2003 3922 988 43318 en

Power Handling Capacity

Page 106
Image 106
Bosch Appliances 3922 988 43318 manual Power Handling Capacity, Power Handling Capacities