Digital Congress Network Installation

and Operating Manual Chapter 6 - DCN Camera Control

 

en 6-5

 

 

 

 

Camera Control

6.1.4.6 Installation of Camera Control in DCN system with PC control

 

CCU = 1 // COM-port 1 . . 4

1.

Requires DCN software release version 8.0 or higher

 

Video = 2 // COM-port 1 . . 4

 

2.

Requires a permanent connection in the following systems:

 

 

 

Other fixed settings are:

Baudrate

=

19200

Databits

=

8

Parity

=

none

Stopbits

=

1

NOTE: The default video switcher communication settings should NOT be changed

5. Communication settings:

1.Refer to DIP-switch S14 settings on the ‘Trunk Communication Board’ (TCB4 (see Chapter 4.6).

2.For multi-CCU systems the correct settings must be present in the CCU_CFG file of the Multi- CCU control software LBB 3586 (see Table 5-8:and Table 5-9:).

3.The default communication settings of the video switcher are the same as used in a DCN stand-alone system.

Single CCU system: direct connection between CCU and video switcher (see FIG 6-3(1)).

Multi-CCU system: direct connection between Master CCU PC and the video switchers (see FIG 6-3(3)).

3.Install software package LBB 3588/00 on the DCN control PC (server PC in a ‘Multi-PC system).

4.Refer to relevant software manual.

6.1.4.5Installation of Camera Control software on the temporary PC

1.Install the ‘Stand-alone’ Camera Control software package LBB 3562/00.

2.Use the software program to configure and set up camera positions. On completion, all data and configuration settings will be automatically downloaded to the CCU.

3.Once camera positions are configured remove the temporary PC and make a direct connection as follows:

Single CCU system: direct connection between CCU and video switcher (see FIG 6-3(1)).

Multi-CCU system: direct connection between Master-CCU and the video switchers (see FIG 6-3(3)).

4. Refer to relevant software manual.