Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-9

 

 

10.4.3 Graph reference examples

FIG 10-12in combination with the PCF graph (FIG 10-10)gives examples of how to calculate the PCF value of a single trunk-outlet. Using these examples, the total PCF value of all three trunk-outlets of a CCU can be calculated.

TS

=

Trunk-splitter

DA1 = Dual Audio Interface units

TT

=

Table-top discussion units

MPC = Multi-purpose Connection units

CON

=

Concentus units

 

NOTE: (1 m = 39.37 in)

GRAPH REFERENCE

Y axis

X axis (max.)

 

 

 

 

 

 

 

 

 

 

 

 

 

PCF

Ext. Cable (m) BLOCK DIAGRAMS

 

 

 

 

 

 

 

 

PCF CALCULATION

 

 

 

 

 

 

 

Tap-off

 

 

 

 

TT = 59 x 1 PCF = 59 PCF

 

TT

1

TT 49

 

 

TT

50

TT

59

 

 

TS

 

 

TS = 1 x 1 PCF =

1 PCF

60

0

 

 

 

 

 

 

 

 

 

 

TOTAL = 60 PCF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 x 2 m = 100 m

 

 

 

9 x 2 m = 18 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAI = 40 x 1.5 PCF = 60 PCF

 

 

 

DAI

1

 

 

DAI

40

 

 

 

 

TOTAL = 60 PCF

60

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 x 2 m = 80 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPCU = 30 x 2 PCF = 60 PCF

60

0

 

MPC

1

 

 

MPC

30

 

 

 

 

TOTAL = 60 PCF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 x 2 m = 60 m

 

 

 

 

 

 

 

 

 

 

 

 

 

CON

1

 

 

 

CON

24

 

 

CON = 24 x 2.5 PCF = 60 PCF

 

 

 

 

 

 

 

 

 

TOTAL = 60 PCF

60

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 x 2 m = 48 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TT = 34 x 1 PCF =

34 PCF

 

 

TS

Tap-off

TT

1

 

 

 

TT

34

 

TS = 1 x 1 PCF =

1 PCF

35

100

 

 

 

 

 

 

 

 

TOTAL = 35 PCF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Ext. cable

=

60 PCF

 

100 m

 

 

34 x 2 m = 68 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ext. cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAI = 22 x 1.5 PCF =

33 PCF

 

100 m

TS

 

DAI

1

 

 

 

DAI

22

 

TS = 1 x 1 PCF =

1 PCF

 

Tap-off

 

 

 

 

TOTAL = 34 PCF

 

35

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Ext. cable =

60 PCF

 

 

 

 

22 x 2 m =44 m

 

 

 

 

 

 

 

 

 

Ext. cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPC = 17 x 2 PCF = 34 PCF

 

100 m

TS

Tap-off

MPC

1

 

 

 

MPC

17

 

TS = 1 x 1 PCF =

1 PCF

 

 

 

 

 

 

 

 

 

TOTAL = 35 PCF =

 

35

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Ext. cable =

 

60 PCF

 

 

 

 

17 x 2 m = 34 m

 

 

 

 

 

 

 

 

 

Ext. cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CON

1

 

 

 

CON

13

CON =13 x 2.5 PCF = 32.5 PCF

 

100 m

TS

 

 

 

 

TS = 1 x 1 PCF =

1 PCF

 

Tap-off

 

 

 

 

 

 

 

 

TOTAL = 33.5 PCF =

 

35

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+ Ext. cable =

 

60 PCF

 

 

 

 

13 x 2 m = 26 m

 

 

 

 

 

 

 

 

 

Ext. cable

 

 

 

 

 

 

 

 

 

 

 

 

FIG 10-12 PCF Calculation examples for a single trunk-line

Bosch Security Systems 04-2003 3922 988 43318 en

Calculating the PCF of a System with respect to cable length

Page 113
Image 113
Bosch Appliances 3922 988 43318 manual Graph reference examples, Con