Digital Congress Network Installation and Operating Manual Chapter 4 - Central Control Equipment

en 4-10

 

 

DIP Switch S12

8 7 6 5 4 3 2 1

S12 ON

Address Settings 0 to 31

Select a different address for every CCU installed. Use switch positions 4 to 8 only)

Switches 1,2 and 3 not available for selection

(DO NOT CHANGE)

DIP-Switch S12

The decimal value assigned to each DIP-switch is as follows:

SW 8

ON = 1

LSB (Least Significant Bit)

SW 7

ON = 2

 

SW 6

ON = 4

 

SW 5

ON = 8

 

1 S12

5

6

3

Jumper X32

 

 

 

 

(NOT PLACED)

SW 4

ON = 16 MSB (Most Significant Bit)

 

 

SW 3

OFF *

8 7 6 5 4 3 2 1

 

X11

 

 

S12 ON

D1 D2 D3

D4 D5 D6

 

X31A

 

IC2

IC1

X32

X25

1

IC200

X10

8 7 6 5 4 3 2 1

S13

ON

X29

X24

SW 2

OFF *

SW 1

OFF *

*DO NOT CHANGE !

EXAMPLE SETTING (Address 25)

8 7 6 5 4 3 2 1

S12 ON

2S13

DIP Switch S13

8 7 6 5 4 3 2 1

ON

Input/Output (I/O) settings (04E0 HEX) ! Default settings DO NOT CHANGE

NOTE: S13 is shown in its default position

4

Jumper X24 (PLACED)

FIG 4-6 Multi-CCU PCB for CCU LBB 3500/35 (DIP-switch and jumper settings)

Bosch Security Systems 04-2003 3922 988 43318 en

Multi-CCU card

Page 64
Image 64
Bosch Appliances 3922 988 43318 manual 6 5 4 3 2 S12 on, Example Setting Address