10.3.2 Using Tap-Off unit LBB 4115/00

The Tap-off unit LBB 4115/00 (FIG 10-5)provides short-circuit protection on the Tap-off connector. Each tap-off connector can accommodate up to a maximum of 2.5 PCF including a DCN units extension cable; for example:

10.3.3 Maximum cable lengths using Trunk-outlets and/or Tap-offs

Extension cables are used to extend the length of cable on DCN system units.The length of cable used, directly affects the PCF value of a system.

Table-top units

- 2 x Concentus Delegate, Chairman units or Interpreter Desks

Flush mounted units

-1 x Dual Audio Interface unit

or 1 x Multi-purpose connection unit or 5 x Channel selector units.

NOTE: The Tap-off connector can handle up to 2.5 PCF per outlet (1x Concentus unit per tap-off)

Tap-offs

Trunk-line

LBB 4115/00 Trunk-line

Trunk-line

LBB 4115/00 Trunk-line

 

Tap-offs see Note

System limits (FIG 10-6)

1.The total cable length (using standard LBB 4116/xx cable) between the CCU and the last unit in any branch of the system must not exceed 250 m (820 ft.).This includes all extension cables and the 2 m (6.5 ft.) cable attached to each system unit.

2.The total length of the cable from the CCU to the first regenerative tap-off (i.e. from Trunk Cable Splitter LBB 4114/00, Audio Media Interface Unit LBB 3508/00 or Extension Power Supply Unit LBB 4106/00 must not exceed 100 m (328 ft.).

3.The total length of the cable between regenerative tap-offs outputs must not exceed 100 m (328 ft.).

Port 1

Rec.

Line

Trunk

In

 

In

 

Out

 

Out

115 V -T4A 230 V -T2A

 

 

Symmetrical

 

LBB 3500/xx

Max. cable length = <100 m (328 ft.)

 

Max. cable

 

Trunk-line

 

 

 

length =

 

 

 

< 100 m

 

 

 

(328 ft.)

Tap-off outlet

 

 

Max. cable

 

Regenerative

length =

 

< 100 m

 

tap-off

 

(328 ft.)

 

LBB

4114

 

Tap-off outlet

LBB

3508

 

 

LBB

4106

 

Termination plug LBB 4118/00

(for use with Channel selector panels LBB 3524/10 and LBB 3526/10)

Regenerative

 

tap-off

 

LBB 4114

 

LBB 3508

Max. cable length = <100 m (328 ft.)

LBB 4106

 

Tap-off outlet

Max. cable length = <50 m (164 ft.)

Trunk outlet

FIG 10-5 LBB 4115/00 Tap-off unit limitations

FIG 10-6 Maximum cable lengths

 