Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-16

 

 

FIG 10-20 Multi-CCU configuration and connection

10.9 Remote Controller

The DCN system provides a facility for connecting to a ‘Remote controller. The remote controller can be custom built to your requirements enabling remote control of the following functions”

Microphone management

Parliamentary voting

Attendance registration

Dedicated control panels or control devices such as touch screens for example (available from companies such as Creston and Panja) along with dedicated software interfaces can be used.

NOTE: Remote control is only available with the following CCU’s:

LBB 3500/15 and LBB 3500/35. The CCU uses its RS 232 serial COM-ports for remote control.The communication between the CCU and the ‘Remote controller’ is message based (remote functions and update notification). Messages are transported as binary streams of bytes. (Refer to Software User Manual for Remote Control software LBB 3587).

The remote control interface must be configured by setting DIP-switches (S14) on the Trunk Communication Board (TCB 4) See Chapter 4.7.

Requirements

1.The dedicated ‘Remote control’ software package LBB 3587/00 MUST BE installed on an external (remote PC). This remote PC must be installed with the operating system DOS 5.0 or higher and connected to the CCU using an RS232 cable (see Installation).

2.The DCN embedded software version MUST BE 7.00 or higher.

10.9.1Installation

The ‘remote control’ interface software LBB 3587 can be installed in a ‘Single or a Multi CCU system. During installation, options are available for changing the COM-port settings of the remote PC.

 

 

 

NOTE: For detailed functionality, installation, commands and communication

 

 

 

 

DCN

protocols refer to the user documentation delivered with the Remote control soft-

 

Software

ware package LBB 3587/00. Extended information is available on request.

 

Manuals

 

 

 

 

 

 

 

 

 

BOSCH

 

 

 

 

 

1. Single CCU System (LBB 3500/15 and LBB 3500/35 (FIG 10-21)

CCU types LBB 3500/15 and LBB 3500/35 have two RS232 serial ports (Port 1 and Port 2) located at the rear of the unit. An RS-232 cable with 1 to 1 wiring (RS232 extension cable) is used to connect the CCU to the remote controller. Note that these CCU’s uses hardware handshaking with the CTS and RTS signals. All other ‘handshake’ signals are internally chained together in the CCU to form the appropriate signals for the remote controller. The maximum cable length between the CCU

and the ‘Remote controller’ should not exceed 5 m (16.4 ft.). Where longer distances are required an ‘interface unit’ should be used to ensure correct transmission.

NOTE: The communication protocol and a higher baud-rate for the serial COM-port can be adjusted as necessary (see Chapter 4.6 and Chapter 5.7).

OPEN INTERFACE

 

 

 

 

Remote PC

 

DCN Control PC

 

 

 

 

 

 

PC Network card

 

 

 

 

 

LBB 4115/00

Remote control

 

 

 

 

LBB 4114/00

 

LBB 3500/15 or LBB 3500/35

software LBB 3587

 

 

 

 

 

 

INSTALLED

RS232

Port 1

Rec. Line

Trunk

 

 

 

 

In

In

 

 

 

Port 2

Out

Out

115V-T4A 230V -T2A

 

 

 

Symmetrical

 

 

 

 

 

RS232

 

 

 

 

Remote

 

 

 

 

Controller

 

 

 

SINGLE CCU SYSTEM

 

 

 

CD 1

 

 

1. CD

 

 

Rx 2

 

 

2. Rx

 

 

Tx. 3

 

 

3. Tx

 

RS232

DTR 4

 

 

4. DTR

 

 

GND 5

 

 

5. GND

 

 

DSR 6

 

 

6. DSR

 

 

RTS 7

 

 

7. RTS

 

 

CTS 8

 

 

8. CTS

 

 

RI 9

 

 

9. RI

 

 

Male

 

 

Female

 

FIG 10-21 Remote control Single CCU System

Bosch Security Systems 04-2003 3922 988 43318 en

Remote Controller

Page 120
Image 120
Bosch Appliances 3922 988 43318 manual Remote Controller, Multi-CCU configuration and connection