Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-3

 

 

10.3 Trunk outlets and Tap-offs

 

 

 

 

The Extension Power Supply Unit LBB 4106/00, Audio Media Interface Unit LBB 3508/00,Trunk-cable

1

 

 

 

splitter LBB 4114/00 and Tap-off Unit LBB 4115/00 all have Trunk outlets and Tap-offs. Trunk-outlets

 

LBB 3508 Audio Media Interface Unit

are used for loop-through of the DCN trunk-line, and tap-offs are used for trunk-cable splitting.These

 

 

 

 

 

units have regenerative Tap-offs, regenerating the digital DCN signal.

 

 

 

 

FIG 10-2shows the Trunk outlets and Tap-offs of the following units:

 

Output 1 Output 2 Output 3 Output 4

Trunk

Tap-off

 

 

 

 

1. Audio Media Interface Unit LBB 3508/00

 

 

 

115 V -T4A 230 V -T2A

 

 

 

 

2. Extension Power Supply unit LBB 4106/00

 

 

 

 

3. Trunk-cable splitter LBB 4114/00 and Tap-off unit LBB 4115/00

 

Trunk-outlet

Tap-offs

 

 

10.3.1 Tap-off limitations

 

 

 

 

The number of serial tap-off connections from the CCU to the last tap-off in its chain should not

 

 

 

 

exceed 4. Any unit connected thereafter will not function. See FIG 10-3.

 

 

 

 

 

2

LBB 4106/00 Extension Power Supply Unit

 

 

Trunk

Tap-off

11- 5V T 4A 2 -30VT2

In

Trunk-outlet Tap-offs

3

 

 

 

 

 

 

 

LBB 4114/00 Trunk-cable splitter

 

 

 

 

 

 

 

LBB 4115/00 Tap-off unit

Trunk-in

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk-out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tap-offs

FIG 10-2 Trunk-outlet and tap-off connections