Digital Congress Network Installation and Operating Manual Chapter 4 - Central Control Equipmenten 4-7

4.5.2 S9 DIP-Switch settings

4.5.3 Jumper settings

See FIG 4-5for location, and Table 4-3:for functionality of the DIP-switches.

See FIG 4-5for location, and Table 4-4:for functionality of the jumpers.

Table 4-3:

S9 DIP-switch settings

 

TCB4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 1

 

 

ON*

 

Chairman priority

tone ON (default).

 

 

 

 

 

 

 

 

OFF

 

Chairman priority

tone OFF

SW 2

 

 

ON

 

Audio ‘Mix-Minus’ mode activated in combination with SW3 = OFF

 

 

 

 

 

 

 

 

OFF*

 

Normal Operation (default).

SW 3

 

 

ON

 

Audio ‘Insertion’ mode activated in combination with SW2 = OFF

 

 

 

 

 

 

 

 

OFF*

 

Normal Operation (default).

SW 4

 

 

OFF*

 

Floor distribution ON (default).

 

 

 

 

 

 

 

 

ON

 

No floor distribution on unused language channels

SW 5

 

 

OFF

 

Reserved (IMPORTANT: must not be changed)

SW 6

 

 

ON

 

Active microphones and request will be permanently switched off if

 

 

 

 

 

 

 

 

 

 

 

 

the priority function of the chairman unit is used. (default).

 

 

 

 

 

 

 

 

OFF*

 

Active microphones will be switched off temporarily if the priority

 

 

 

 

 

 

 

 

 

 

 

 

function of the chairman unit is activated.

SW 7

 

 

OFF

 

Reserved (IMPORTANT: must not be changed)

SW 8

 

 

ON

 

Switching on the CCU will activate the BOOT software, this makes a

 

 

 

 

 

 

 

 

 

 

 

 

new download possible. All memory settings will be erased and

 

 

 

 

 

 

 

 

 

 

 

 

returns to the default settings.The unit addresses will not be erased.

 

 

 

 

 

 

 

 

OFF*

 

Normal operation (default).

* = default setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP switch S9 (default settings)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S9

 

 

ON

 

 

 

 

 

 

 

 

 

switches 5 and 7 are ‘RESERVED’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Must NOT be changed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

 

3 4 5

6 7 8

 

 

 

 

see FIG. 4-3 and FIG 4-5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-4: Jumper settings

 

Jumper

Default

Function

3

X13

1 & 2

Jumpered to provide SRAM Battery back-up

 

 

 

Open when removing back-up battery. (Position 2 & 3)

7

X14

1 & 2

Watchdog active

 

 

 

Open for service purposes. (Position 2 & 3)

 

 

 

 

Bosch Security Systems 04-2003 3922 988 43318 en