Bosch Appliances 3922 988 43318 manual Control PC requirements, ‘DIRECT’ DCN PC control, PC-card

Models: 3922 988 43318

1 172
Download 172 pages 15.34 Kb
Page 78
Image 78

Digital Congress Network Installation and Operating Manual Chapter 5 - Control using PC

en 5-8

 

 

EXAMPLE 2: Multi-CCU System with control PC and Camera control

IMPORTANT:The LBB 3510/00 PC Network card CANNOT be used in a PC running Windows NT 4.0 or 2000.

Simultaneous use of the PC-Network card and ‘DIRECT’ connection is NOT possible.

NOTES:

1. When using the ‘DIRECT’ method the

functions of the PC-Network card are NOT

available (i.e. headphones and intercom).

These functions are available on the DCN

Concentus units or with the ‘Multi-purpose

Control PC requirements:

 

Control PC

 

-Windows 95, 98, NT 4.0 or 2000

-Start-up software LBB 3590.

- DCN software application modules as

 

 

required.

COM 1

COM 2

 

‘DIRECT’ DCN PC control

 

 

- Master CCU Port 1

RS232

RS232

- Protocol: FULL

- Baudrate: 115.2k

Male

Male

 

 

The COM-port for Master CCU control is selected during software installation. Select COM 1.

By default an ID-chip card encoder is connected to COM 2. COM 2 settings can be changed in the dcn.ini file (see Table 5-11).

e.g. Card encoder or serial printer etc.

connection unit’ LBB 3540/15.

2. The baud-rate setting of the Master CCU

PC port and the corresponding Control PC

port must be the same.The available baud

rate settings are 9600, 19200, 38400, 57600

and 115200. Baud rate setting on the Master

CCU PC must be set in the CCU_CFG file

(SERIAL SPEED I <baud-rate>). For more

information refer to the README.TXT file

of the Multi CCU software LBB 3586. Baud-

rate setting on the DCN Control PC must

be set in the DCN.INI file.This file can be

found in the WINDOWS or WINNT

directory.

[Server]

SerialLink=Yes

 

 

 

 

Master CCU PC

 

Master CCU PC requirements:

Control PC

OS/2 PC

LBB 3511/00

 

- OS/2 version 3.0 Warp or higher

DCD 1

 

1

DCD

Multi-CCU

 

- Multi-CCU software LBB 3586

 

 

- UPS (Uninterrupted Power Supply)

RD 2

 

2

RD

PC-card

 

TD 3

 

3

TD

COM 1

COM 2

recommended

DTR 4

 

4

DTR

 

 

 

 

 

GND 5

 

5

GND

 

 

Video switcher (if applicable)

DSR 6

 

6

DSR

 

 

RTS 7

 

7

RTS

 

 

 

CTS 8

 

8

CTS

 

 

Power

 

 

 

 

 

 

ALLEGIANT Video System

RI 9

 

9

RI

RS232

RS232

Code Out

 

Alarm

Female ‘Null modem ’

 

 

Male

Male

Battery Low

Female

 

 

Status

 

 

 

9-pole D-type cable connections

 

 

See Chapter 6. for installation details

For COM-port settings of the Master CCU PC

 

 

 

75 Ohm Coax cable

 

LTC 8506/00

 

 

 

(see Chapter 5.7)

 

 

 

 

[Serial Link]

ComPort=1

Baudrate=<Baudrate>

FullProtocol=Yes

1

 

LBB 3500/35

 

 

 

 

Port 1

Mult-CCU

 

Rec .

Line

Trunk

 

 

In

 

In

 

I n

Out

 

 

 

 

 

 

 

Port 2

 

 

Out

 

Out

115V -T4A 230V -T2A

 

 

 

 

 

Symmetrical

 

OUT

To next Multi-CCU

 

 

 

LBB 3500/35

n (max.16)

 

 

 

 

Port 1

Mult-CCU

 

Rec .

Line

Trunk

 

 

In

 

In

 

I n

Out

 

 

 

 

 

 

 

Port 2

 

 

Out

 

Out

115V -T4A 230V -T2A

 

 

 

 

 

Symmetrical

 

 

 

IN

 

 

 

 

From Multi-CCU

FIG 5-7 Multi-CCU System with control PC and Camera control