Digital Congress Network Installation and Operating Manual Chapter 8 - Information Displays

en 8-3

 

 

Data Format Specifications: RS232 Output

9600/19200 baud (selected by dip switch)

8 data bits

1 stopbit

No parity

Electrical specifications according to RS232 C standard.

Further information concerning the Data Distribution Board is available on request.

Parallel input and output connections

When using the board’s parallel input or output, either the solder pads (6) and (9) or the Micro Match connectors (5) and (11) can be used.Two 20-pole male Micro Match connectors are provided with the board.These connectors can be connected to a 20-pole flat cable using a special connecting tool (not provided).

Board Address setting

DIP Switch

248

249

250

251

252

253

254

255

DP6

0

1

 

0

1

0

1

 

0

1

DP7

0

0

 

1

1

0

0

 

1

1

DP8

0

0

 

0

0

1

1

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUTS

9

 

INPUTS 6

 

 

 

 

 

 

Solder Pad

Micromatch

 

 

Solder Pad

 

Micromatch

 

 

 

 

 

L to R

connector

 

 

L to R

 

connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vcc

1

 

 

Vcc

 

1

 

 

 

 

 

D00

2

 

 

U00

 

2

 

 

 

 

 

D01

3

 

 

U01

 

3

 

 

 

 

 

D02

4

 

 

U02

 

4

 

 

 

 

 

D03

5

 

 

U03

 

5

 

 

 

 

 

D04

6

 

 

U04

 

6

 

 

 

 

 

D05

7

 

 

U05

 

7

 

 

 

 

 

D06

8

 

 

U06

 

8

 

 

 

 

 

D07

9

 

 

U07

 

9

 

 

 

 

 

Gnd

10

 

 

Gnd

 

10

 

 

 

 

 

Vcc

11

 

 

Vcc

 

11

 

 

 

 

 

D08

12

 

 

U08

 

12

 

 

 

 

 

D09

13

 

 

U09

 

13

 

 

 

 

 

D10

14

 

 

U10

 

14

 

 

 

 

 

D11

15

 

 

U11

 

15

 

 

 

 

 

D12

16

 

 

U12

 

16

 

 

 

 

 

D13

17

 

 

U13

 

17

 

 

 

 

 

D14

18

 

 

U14

 

18

 

 

 

 

 

D15

19

 

 

U15

 

19

 

 

 

 

 

Gnd

20

 

 

Gnd

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG 8-5 Data Distribution Board connection details

8.1.1 Remote Switching Solutions

Using the Data Distribution Board LBB 3512/00 an interface facility is provided for the control of external equipment such as loudspeaker group switching and other special switching facilities (FIG 8- 6).

Application 1.

Application 1, gives a typical solution when using the data distribution board in combination with an interpreter desk.The interpreter desk includes an external message key, this key when pressed can alert for example, some one in the secretariat via an LED indication panel or as a ‘speak-to-fast’ indication to the chairman.

Application 2.

Application 2, shows a typical example using the DCN system as a transparent control path using two data distribution boards LBB 3512. Using this example a variety of switching solutions are possible- for example, to switch lights on or off, or even to drive a motor that will open or close curtains as used in large congress halls etc.

APPLICATION 1

APPLICATION 2

External message key

External switching

device

 

Sectional view

 

 

 

 

Parallel input connector

 

 

Interpreter desk

 

 

 

 

 

 

 

 

 

 

(PIN 1-15)

 

 

 

 

 

 

 

 

 

 

LBB 3520/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Active mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DDB 1

 

(CCU selected

 

 

 

 

 

 

System cabling

 

LBB 3512

 

address DP ON)

Passive mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

address 255

 

DDB

 

 

 

 

 

 

 

 

 

 

 

 

 

DCN

 

 

 

 

LBB 3512

 

Parallel output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System cabling

 

 

 

 

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

Passive mode

Parallel output

 

 

 

 

(PIN 1 - 15

 

 

 

 

 

 

 

 

 

connector

 

 

 

 

PIN 16 reserved)

 

DDB 2

 

(Address:

(PIN 1 - 15)

 

 

 

 

 

 

 

 

 

 

 

 

LBB 3512

 

248 - 254)

 

 

Customized Remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indication panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indication panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG 8-6 Remote switching solutions

Bosch Security Systems 04-2003 3922 988 43318 en

LBB 3512/00 Data Distribution Board

Page 99
Image 99
Bosch Appliances 3922 988 43318 Data Format Specifications RS232 Output, Parallel input and output connections, Application