Digital Congress Network Installation and Operating Manual Chapter 10 - Installation Techniques

en 10-11

 

 

10.6.2 System layout (without extension units)

 

10.6.3 System with Extension units

 

Using extension cables,Trunk-splitters and Tap-off units, the length of cable on a system unit can be

FIG 10-15shows the Audio Media Interface unit connected directly to the Central Control Unit,

lengthened, and cable runs can be laid out in diverse directions. FIG 10-14gives a typical layout

however in principle the unit can be connected to any convenient point within the DCN network

configuration using a Trunk-splitter and extension cables LBB 4116/xx.

 

cabling.

 

 

 

 

 

 

The illustration shows a centralized configuration where all the DCNs Central Control equipment is

 

 

installed in a 19”-inch rack for example.

 

 

 

In a de-centralized configuration, the Extension Power Supply unit and the Audio Media Interface unit,

Trunk-line

 

are placed in different locations separated from the Central Control equipment.

 

 

 

 

 

 

 

LBB 4114/00

To CCU

NOTE: The example below uses a Central Control Unit LBB 3500/05 having a total power

handling capacity of

90 PCF. Using a Central Control Unit LBB 3500/15 the power han-

Tap-offs

 

dling capacity is limited to 180 PCF (max. 60 PCF per output).

 

Trunk-line

 

 

 

 

 

 

 

 

 

 

CENTRALISED SYSTEM

 

 

 

LBB 3500/05

LBB 3508/00

 

 

 

Port 1

Rec.

Line

Output 1 Output 2 Output 3 Output 4 Trunk

Tap-off

 

 

Trunk

 

 

 

 

In

In

 

 

 

 

 

 

 

 

 

Out

Out

115 V -T4A 230 V -T2A

115 V T4 A 230- V T2A

 

 

 

 

Symmetrical

 

 

 

 

PCF 90 (max.)

PCF 90 (max.)

 

Tap-offs

 

DE-CENTRALISED SYSTEM

 

LBB 4106/00

Trunk-line

 

To CCU

Port 1

Rec.

Line

 

 

 

 

 

 

 

Trunk

Trunk

Tap-off

 

 

 

In

 

In

 

 

Trunk-line

 

 

 

 

 

 

LBB 4114/00

 

Out

 

Out

115 V -T4A 230 V -T2A

 

 

 

 

 

 

 

 

11 5V-T 4A 2 30V -T2A

 

 

 

 

Symmetrical

 

 

In

 

 

 

 

 

 

 

 

 

FIG 10-14 Unit layout possibilities using trunk-splitters

PCF

60 (max.)

PCF 180 (max.)

 

 

 

 

 

 

LBB 3508/00

 

Output 1 Output 2

Output 3 Output 4 Trunk

Tap-off

 

 

 

115 V T4A 230- V T2A

 

 

 

PCF 90 (max.)

 

FIG 10-15 Typical system interconnection