Pelco C1487M-D operation manual Dome Drive, Switch Locations Table C. Switch Settings for SW1

Models: C1487M-D

1 50
Download 50 pages 21.38 Kb
Page 15
Image 15

DOME DRIVE

CAUTION: Make sure the dome drive locks into

place. Tug downward on the dome drive with moderate pressure to ensure that it stays in place.

1.Turn on power to the back box. The red LED should light to indicate power.

If the LED does not light, correct the trouble before proceeding. Refer to the Trouble- shooting section.

If the light is operating, you may either leave the power on and continue with the installation, or you may turn the power off before proceeding further.

2.Set the switches on the bottom of the dome drive. Refer to Figure 14 and Table C for the settings for SW1.

Refer to Figure 14 and Tables D and E for the settings for SW2.

3.Install the dome drive in the back box: Line up the green drive eject tab on the dome drive with the green label on the back box and the red static tab with the red label on the back box. Raise the dome drive into the back box and push on the ends of the tabs until they both click into place on the back box.

4.Turn on power, if it is not on. Listen for the fan operating. If the fan does not work, the dome will overheat and shut down. If the fan does not work, return the back box electronic assembly and dome drive to the factory for repair. Refer to the Back Box Electronic Assembly Removal section.

Proceed to the Lower Dome section.

SW 1

ON

1 2 3 4 5 6 7 8 OFF

ON

1 2 3 4 5 6 7 8 OFF SW 2

SW 1

ON

1

8 OFF

ON

18 OFF

SW 2

Figure 14. Switch Locations

Table C. Switch Settings for SW1

Control Type

 

 

 

Switch Setting

 

 

 

 

SW1-1 SW1-2

SW1-3

SW1-4 SW1-5

SW1-6

SW1-7 SW1-8

 

 

 

 

 

 

 

 

 

Coaxitron®

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF**

P-Type Control

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF**

D-Type Control

OFF

ON

OFF

OFF

OFF

OFF

OFF*

OFF**

NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.

D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500 and CM8500 controllers or with American Dynamics control systems using the AD2083 Translator.

P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 control systems. * OFF- Use with controllers that have more than 32 presets.

ON- Use with American Dynamics controllers (32 presets).

** OFF - Use with all control systems except CM9502 with variable speed keyboards. For CM9502 with fixed speed keyboards, set switch OFF.

ON - Use with CM9502 with variable speed keyboards for smoother joystick control.

Pelco Manual C1487M-D (7/99)

15

Page 15
Image 15
Pelco C1487M-D operation manual Dome Drive, Switch Locations Table C. Switch Settings for SW1