To change the line synchronization settings:

1.Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear.

2.If the cursor (>) is not beside Line Sync, move the joystick up or down to position the cursor beside Line Sync.

3.Press the Iris Open button on your keyboard. Another menu will appear with the Line Sync and Line Sync Phase selections.

4.Move the joystick up or down to position the cursor beside one of the choices.

LINE SYNC - The cursor moves to one of two choices: On or Off. Move the joystick up or down to toggle between them.

Press the Iris Open button to select the choice. If you changed to Off, the camera may reset itself as it adjusts to the new synchronization. If the camera resets, it will only affect the line synchronization. It will not change any other camera parameters, such as auto focus or auto iris.

Press the Iris Close button if you do not want to change the setting.

LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or down to change the value.

Press the Iris Open button to select the choice. The value represents the phase angle in tenths of a degree between 0 degrees and 359 degrees for Spectra II™ and 0 to 350 degrees for Spectra Lite™. For example, 900 is 90 degrees, 1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button on your keyboard to select your choice. The Line Sync setting will change to On. The camera may reset or the picture on your monitor may wiggle when you change the phase angle. If the camera resets, it will only affect the line synchronization. It will not change any other camera parameters, such as auto focus or auto iris.

Press the Iris Close button if you do not want to change the setting.

POWER-UP MODE

This feature lets the dome resume a desired condition following power-up. The menu includes the following choices. (An asterisk denotes items that apply to the Spectra II™ only.)

Default - On power-up, the dome goes through a configuration cycle and stops at zero reference, showing “Configuration Done,” address, and mode settings on the screen.

Park - The dome moves to preset 1 when the power-up sequence finishes. The only text on the screen is the preset label (if any is programmed).

Scan Auto - The dome initiates scan mode when the power-up sequence finishes. Again, there is no text.

Scan Frame - The dome initiates a frame scan when the power-up sequence finishes.

Scan Rand - The dome initiates a random scan when the power-up sequence finishes.

Full Pat* - The dome initiates its programmed pattern when the power-up sequence finishes. The length can be set to 1.5, 3, or 6 minutes.

Half Pat 1* - The dome initiates the first half-pattern when the power-up sequence finishes. The length can be set to .75, 1.5, or 3 minutes.

Half Pat 2* - The dome initiates the second half-pattern when the power-up sequence finishes. The length can be set to .75, 1.5, or 3 minutes.

The default setting is Default.

36

Pelco Manual C1487M-D (7/99)

Page 36
Image 36
Pelco C1487M-D operation manual POWER-UP Mode