To select the
1.Program preset 95 (28 if in
2.If the cursor (>) is not beside Power Up Mode, move the joystick up or down to position the cursor beside Power Up Mode.
3.Press the Iris Open button to enter the Power Up Mode submenu.
4.Press the Iris Open button to move the cursor to the right.
5.Move the joystick up or down to cycle through the selections. Stop on the item you want to select.
6.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.
AUX MODE
(This section applies to Spectra II™ only.)
This feature defines the output relay as either Normal (under control of the head end), Latching (pressing the AUX key turns on the AUX and the next press of the AUX key turns it off), or Alarm (any alarm input activates the AUX).
To change the AUX mode:
1.Program preset 95 (28 if in
2.If the cursor (>) is not beside AUX, move the joystick up or down to position the cursor beside AUX.
3.Press the Iris Open button to enter the AUX submenu.
4.Move the joystick up or down to position the cursor next to either Aux 1 mode or Aux 2 mode.
5.Press the Iris Open button. The cursor will move to the right beside the word Normal, Latching, or Alarm.
6.Move the joystick up or down to toggle between Normal, Latching, or Alarm.
7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM RESUME
(This section applies to Spectra II™ only.)
This mode lets the dome resume its previous activity (scan, pattern, or previous position) after all alarms are cleared.
To change the alarm resume mode:
1.Program preset 95 (28 if in
2.If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to position the cursor beside Alarms, Zone Blank.
3.Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4.Move the joystick up or down to position the cursor beside Alarm Resume.
Pelco Manual | 37 |