BACK BOX CONNECTIONS

WARNING: Make sure you wire power to the outer con- nectors of the terminal block and ground to the middle connector. Otherwise, you could damage the dome.

DOME 1

POWER

DOME 2

POWER

DOME 3

POWER

EXAMPLE: If each dome requires 30 vA, three domes require a transformer with a minimum output of 120 vA (refer to the Wiring section for transformer require- ments).

Figure 11. Transformer Wiring

Refer to Figure 12 or 13 to attach the wiring to the interconnect circuit board inside the back box. Also refer to Figure 8 or 9 if necessary.

1.Earth Ground - Connect earth ground to the middle connector on the power connector.

2.Power - Connect 24 VAC from the transformer to the outer terminals on the power connector. It does not matter which lead goes to which terminal.

If you are wiring more than one dome from the same transformer, it is important to wire the power connector in each dome the same way. That is, the wiring from one side of the transformer must be connected to the same connector on each dome. If you reverse the wiring, the cameras will be out of phase with each other and may produce what appears to be vertical roll when switching between cameras. Refer to Figure 11 for a wiring diagram.

3.Video - Connect the coaxial cable to the BNC video connector.

4.Control - If you are using a Coaxitron® controller, control signals will be transmitted over the video coax.

If you are using RS-422 (P or D) control signals, connect the control lines from the controller to the circuit board. Connect the wires as follows:

From controller

To 4-Wire terminal on circuit board

 

 

RX-

TX-

RX+

TX+

TX-

RX-

TX+

RX+

 

 

 

 

 

 

CONNECTOR

 

HTR/FAN

VIDEO

FOR OPTIONAL

 

TRANSLATOR

RS-422

 

 

 

 

 

SUBASSEMBLY

CONTROL

 

 

 

 

 

 

 

SIGNALS

1

 

 

 

 

 

RX–

 

 

2

 

DOME DRIVE

 

 

 

 

5

ALARMS

RX+

 

3

 

CONNECTOR

 

4

 

 

 

 

TX–

 

 

 

 

 

 

6

 

TX+

 

 

7

 

 

 

 

GND

 

 

 

 

NO

RELAY

 

 

AUX 1

COM

 

 

NC

 

 

 

 

 

 

 

 

AUX 2

 

 

 

GND

 

 

 

 

 

 

FUSE

FAN

 

 

 

 

 

IN

 

24 VAC

 

 

PWR

 

 

 

 

MIDDLE

 

 

 

 

PIN IS

 

 

 

 

GND

 

POWER

 

 

 

 

(24 VAC ONLY)

 

 

1.6 A

 

Figure 12. Interconnect Circuit Board Electrical Connections for Spectra II™

Pelco Manual C1487M-D (7/99)

13

Page 13
Image 13
Pelco C1487M-D operation manual Back BOX Connections, From controller To 4-Wire terminal on circuit board