SPECTRA LITE™ PENDANT COMPONENTS

BB5T-PB

Black pendant-mount back box (CE, UL, cUL)

BB5T-PG

Light gray pendant-mount back box (CE, UL, cUL)

BB5T-PG-E

Same as BB5T-PG except includes heater and sun shield (CE, UL, cUL)

DD5TAC

Dome drive with color camera and lens, NTSC standard (FCC, UL, cUL)

DD5TAC-X

Dome drive with color camera and lens, PAL standard (CE)

LD5PB-0

Smoked lower dome (1/2 f-stop of light loss) for black pendant-mount dome

LD5PB-1

Clear lower dome for black pendant-mount dome

LD5PB-2

Chrome lower dome (2 f-stops of light loss) for black pendant-mount dome

LD5PB-3

Gold lower dome (2 f-stops of light loss) for black pendant-mount dome

LD5PG-0

Smoked lower dome (1/2 f-stop of light loss) for light gray pendant-mount dome

LD5PG-1

Clear lower dome for light gray pendant-mount dome

LD5PG-2

Chrome lower dome (2 f-stops of light loss) for light gray pendant-mount dome

LD5PG-3

Gold lower dome (2 f-stops of light loss) for light gray pendant-mount dome

LD5PG-E0

Same as LD5PG-0 except includes heater

LD5PG-E1

Same as LD5PG-1 except includes heater

SPECTRA LITE™ IN-CEILING COMPONENTS

BB5T-F

Indoor back box for flush mounting in a ceiling (CE, UL, cUL)

DD5TAC

Dome drive with color camera and lens, NTSC standard (FCC, UL, cUL)

DD5TAC-X Dome drive with color camera and lens, PAL standard (CE)

LD5F-0

Smoked lower dome (1/2 f-stop of light loss)

LD5F-1

Clear lower dome

LD5F-2

Chrome lower dome (2 f-stops of light loss)

LD5F-3

Gold lower dome (2 f-stops of light loss)

INSTALLATION FOR IN-CEILING MODELS

To install the dome proceed through the steps in this section, beginning with the Ceiling and Back Box Preparation section.

CEILING AND BACK BOX PREPARATION

NOTE: Use the SCA1 (structural ceiling adapter) if additional support is required.

CAUTION: Be careful not to cut

outside of the line.

If you do, you may not be able to install the back box. Also, the trim ring may not cover the hole.

HARD CEILING

1.Locate the center point where you want to drill a hole in the ceiling. (The ceiling tile cannot be thinner than 0.50 inch [1.27 cm] nor thicker than 1.75 inches [4.45 cm].)

2.Drill a hole in the ceiling using a 3/32-inch drill bit.

3.Remove the compass tool from the parts bag that came with the back box (refer to Figure 4). Press the stud of the compass tool into the hole in the ceiling. Insert a pencil in the hole in the other end of the compass and mark a circle on the ceiling.

4.Carefully cut the circle out of the ceiling.

5.Remove the conduit fitting, lock nut, and safety chain bracket from the parts bag and attach them to the back box as shown in Figure 5.

Proceed to the Wiring section.

ATTACH SAFETY CHAIN HERE

Figure 4. Compass Tool

Figure 5. Conduit Fitting Installation

8

Pelco Manual C1487M-D (7/99)

Page 8
Image 8
Pelco C1487M-D Installation for IN-CEILING Models, Spectra Lite Pendant Components, Spectra Lite IN-CEILING Components