Installation (for qualified installers only) | 1 5 |
Vent Installation
•In addition to the requirements below, follow the requirements provided with the vent.
Vertical Vent Requirements
Vertical Termination (part # 1291)
Use a roof flashing and storm collar
whenever passing through the roof Combustible Framing
Use the Simpson ceiling firestop (#1263) whenever passing through a ceiling (or enclosure and at every floor penetration.
10"
by
10"
Min. 1" clearance from vertical sections to combustible surfaces.
Minimum framing for fire stop
Horizontal Vent
Requirements
Minimum framing
for fire stop
Minimum
12" tall
Minimum 10" wide
Use the Travis firestop (part # 93006094) when passing through a wall. NOTE: make sure the firestop is postitioned correctly so the 3" clearance is allowed above the vent.
1" Min.
Combustible
Surfaces
3" Min.
1" Min.
•Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
•Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired.
•High temperature sealant is recommended at the appliance starter section
connection (use
•If disassembly is required, at time of
•Horizontal sections require a 1/4" rise every 12" of travel
•Horizontal sections require
Travis Industries | 4050114 | 1 0 0 - 0 1 1 4 9 |