Optional Equipment (for qualified installers only) 5 1

2 Attach the blower box to the framing or floorboards of the home following the instructions below.

Wall or Ceiling Mounting

a

Cut a hole between wall

b

Attach the wall mounting

c

Slide the blower, with

framing members for the

brackets to the blower box.

wires, into the hole cut

 

blower assembly.

 

 

 

in step "a". Attach

 

 

 

 

 

with four screws.

5-1/4"

16"*

Mount the bracket to these holes for 2 x 4 walls

Mount the bracket to these holes for 2 x 6 walls

* This blower was designed for framing on 16" centers - construct additional framing if needed.

Floor Mounting

a

Cut a hole between floor joists

b

Attach the floor boot to the blower box with the included screws.

for the blower box.

 

 

 

 

The screws

 

 

 

attach to either

 

5-1/4"

 

of these pairs of

 

 

holes. Use the

 

14"

 

upper pair for

 

 

 

thick flooring, the

 

 

 

lower pair for

 

 

 

thin flooring.

Slide the blower into the hole c cut in step "a". Attach with four

screws.