Maintenance (for qualified service personnel only) 4 1

Maintaining Your Fireplace's Appearance

!Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean prior to turning the heater on. Clean plated surfaces with denatured alcohol and a soft cloth (make sure the fireplace is cool). Other cleaners may leave a film that may become etched into the plated surface.

Clean the glass with soap and water (do not use abrasive cleaners). To remove the glass, follow the instructions on page 29.

Yearly Service Procedure

!Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous situation. The following procedures must be done by a qualified technician.

1Check the pilot flame. It should touch approximately 3/8" of the top of the thermopile and touch the top of the thermocouple (see illustration below). If it does not, contact your dealer for service.

2Shut off gas to the fireplace by turning the gas control knob to "OFF" (see step A under "Starting the Pilot" on page 38). Let the fireplace cool for 15 minutes. Remove the faceplate (see instructions included with face) and glass (see page 29).

3Remove the log set (NOTE: the logs are very fragile - see page 31). If severely deteriorated, replace. Check the logs for sooting. A small amount of soot along the bottom of the logs is normal. If excessive sooting is found, the fireplace will require adjustment. Contact your dealer.

4Clean the burner and inspect the following:

Check the burner for damage.

Check the firebox and area around the pilot to make sure there is no damage.

If any problem is found, discontinue use and contact your dealer for service

Before Disassembly: Check the pilot flame. It should touch the thermopile and thermocouple.

Thermopile

Pilot Hood

Thermocouple

Check the walls and ceiling of the firebox for deterioration.

Make sure the burners are not warped or damaged.

Check the burner holes.

5Replace the log set. Replace the glass (if the glass is damaged, replace it). Make sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal. If it does not, re-align or replace the gasket to insure an air-tight seal. Replace the faceplate.

6Inspect the area behind the access door. Clean if necessary. Check the gas control valve and the gas lines. If any damage is found, discontinue use and contact your dealer for service. Clean the air channels and ducts. Clean out the area near the blower (behind the gas control valve).

7Start the pilot and turn on the main burner. The flames should be orange/yellow and not touch the top of the firebox. If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor the blower operation.

8Inspect the glass. If damage is found, replace the glass (with frame) with Travis Industries glass assembly (glass installation is on 29).

9Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is found near the vent termination.

1 0 Inspect the vent sections. If any damage or dis-connection has occurred, contact your dealer for service.