FireplaceXtrordinair 44 DV XXL EF manual Termination Requirements see the illustration below

Models: 44 DV XXL EF

1 56
Download 56 pages 32.4 Kb
Page 21
Image 21
Roof Surface
11” Min.
6” Min.

Installation (for qualified installers only)

2 1

Termination Requirements (see the illustration below)

!Venting terminals shall not be recessed into a wall or siding.

A Minimum 9" clearance from any door or window

B Minimum 12" above any grade, veranda, porch, deck or balcony

C Minimum 12" from outside corner walls

D Minimum 12" from inside corner walls

E Minimum 11" clearance below unventilated soffits or roof surfaces

Minimum 18" clearance below ventilated soffits

Minimum 6" clearance from roof eaves

NOTE: Vinyl surfaces require 24"

FMinimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

GMinimum 48" clearance from any adjacent building

HMinimum 84" clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building

IMinimum 48" clearance from any mechanical air supply inlet

JMinimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

KMinimum 36" from the area above the meter/regulator (vent outlet)

LMinimum 36" from the meter/regulator (vent outlet)

MMinimum 12” above the roof line (for vertical terminations)

NMinimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

Roof Eaves

E

N

M

E

A

K

G A

F

D C I

L

B

NOTE: Measure clearances to the nearest edge of the exhaust hood.

E

J

H

Use the vinyl siding standoff (#1250) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material

These clearances meet UMC-1994 standards.