FireplaceXtrordinair 44 DV XXL EF manual Electrical Connection, Fireplace junction box

Models: 44 DV XXL EF

1 56
Download 56 pages 32.4 Kb
Page 13
Image 13

Installation (for qualified installers only)

1 3

Electrical Connection

!Make sure the household breaker is shut off prior to working on any electrical lines.

!The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, or ANSI NFPA.

The electrical line must be 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

1Follow the directions below to connect power to the fireplace.

a

Remove the cover from the

fireplace junction box.

Insert the sheathed cable from the power source through b this cable clamp. Once the wires are attached, tighten

the clamp to secure the cable.

WARNING: Make sure power is off from the power lead before conducting any wiring.

Nutdriver

Standard

 

 

Screwdriver

1/4"

d

 

Replace

 

the cover

 

removed

 

in step "a".

Electrical Connector (shipped in the fireplace behind the cover plate)

Attach the common (white), ground (exposed or green) wires, and hot c (black) wires from the power source to the electrical connector (included

with the fireplace). Then attach the connector to the fireplace.

NOTE:

If using the power heat duct, you may wish to route the wiring for it at this point. See the instructions under "Optional Equipment".

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Page 13
Image 13
FireplaceXtrordinair 44 DV XXL EF manual Electrical Connection, Fireplace junction box