Installation (for qualified installers only)

Horizontal Terminations with One Vertical Elbow

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.

N O T E: If you are installing this fireplace with a minimum of vent rise, and are experiencing intermittent pilot outages, you may need to install a pilot shield (SKU 250-00028). Contact your dealer for information.

H2

H1

 

Vertical Elbow

NOTE:

One horizontal elbow (45° or 90°) is allowed. The horizontal vent length is calculated by adding the length before and after the elbow (H1 + H2 = horizontal vent length).

Horizontal sections require a 1/4" rise every 12" of travel.

Horizontal Elbow (45° or 90°)

20' (max)

15feet

10feet

5feet

0feet

0feet

5feet

10feet

15feet

20feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor

 

 

 

Position #5

 

 

 

 

 

 

NOTE:

 

 

 

 

 

Restrictor positions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are based upon lab

 

 

 

 

 

tests. The ideal

 

 

 

 

 

restrictor position may

 

 

Restrictor

vary slightly.

 

 

 

 

 

 

 

 

Position #1

 

Min. 18" Rise Before First Elbow

0feet

5feet

10feet

15feet

20feet

25' (max)

20' (max)

15feet

10feet

5feet

0 feet