Safety Label | 4 5 |
The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is shown below.
Fireplace Xtrordinair 44DVXXL
Vented Gas Fireplace Heater
Report No.
Certified for USA
Tested to: ANSI
VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instruc- tions. Use only approved coaxial direct vent system to vent this appliance to the exterior. See owner’s manual for approved brands of venting.
Minimum Clearances to Combustibles
Faceplate to Adjacent Wall | . . . . | Hearth Extension in Front | . . . . . | 12” | |
Wood Floor Beneath Fireplace | . . . . | 0” | If Fireplace raised 3” Hearth Extension in Front | . . . . . | 0” |
Back to enclosure | . . . . | 1” | Hearth Extension to Sides of Faceplate | . . . . . | |
Top to enclosure (from | . . . . | 0” | Sides to enclosure | . . . . . | 1” |
|
|
| *Faceplate to 8” Mantel (no eyebrow) | . . . . . | 20” |
* See Owner’s Manual For Additional Mantel Clearances and Options. |
|
| |||
|
|
|
|
|
|
| L.P. | N.G. |
| L.P. | N.G. |
Input Rate on “HI” (BTU/Hr) | 58,000 | 58,000 | Minimum Inlet Pressure (inches W.C.) | 11.5” | 5.5” |
Input Rate on “LO” (BTU/Hr) | 44,000 | 44,000 | Manifold Pressure on “HI” (inches W.C.) | 11” | 3.5” |
For natural gas when equipped with the following drill size orifices:
Back #44, Center #43, and Front #45
For propane when equipped with the following drill size orifices:
Back #55, Center #55, and Front #55.
This appliance is equipped for altitudes above 2,000 feet.
Electrical Rating: 115v, 1.5 Amps, 60 Hz
Manufacture |
| 2003 |
| Jan. |
| Apr. |
| Jul. |
| Oct. |
|
Date: |
| 2004 |
| Feb. |
| May |
| Aug. |
| Nov. | 10850 117th Pl. N.E. Kirkland, WA 98033 |
|
|
|
|
| |||||||
|
| 2005 |
| Mar. |
| Jun. |
| Sep. |
| Dec. | |
|
|
|
|
|
| 0361 | |||||
|
|
|
|
|
|
Travis Industries | 4050114 | 1 0 0 - 0 1 1 4 9 |