| 6 | Features and Specifications | |||
|
|
|
|
| |
| Features: | Installation Options: |
|
| |
| - Works During Power Outages (millivolt system) | - Residential or Mobile Home |
| ||
| - | High Efficiency | - Straight or Corner Placement |
| |
| - Optional Thermostat or Remote Control | - Flush or Recessed Face |
| ||
| - Realistic "Wood Fire" Look |
| |||
| - Raised or Floor Hearth |
|
| ||
| - Two Quiet Blowers for Effective Heat Distribution |
|
| ||
| - Internal or External Chase |
| |||
| - | Convenient Operating Controls |
| ||
| - Horizontal or Vertical Vent |
| |||
| - |
| |||
| - Power Heat Duct |
|
| ||
| - | Low Maintenance |
|
| |
|
|
|
| ||
| Heating Specifications: | Natural Gas | Propane | ||
| Approximate Heating Capacity (in square feet)* | Up to 3,000 | Up to 3,000 | ||
| BTU Input Per Hour (from high to low) | 58, 000 – 43,000 | 58, 000 – 44,000 | ||
| BTU Output on High (with blowers on) | 42,920 | 44,080 |
| |
| Efficiency** (with blowers on) | 74 % | 76 % |
| |
| AFUE (Annual Fuel Utilization Efficiency) | 68 % | 69 % |
|
*Heating capacity will vary with floor plan, insulation, use of Power Heat Duct, and outside temperature.
**Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.
Dimensions:
| Vent has an external diameter of 8" | |
Weight: 325 Lbs. |
| |
|
The electrical connection is made in the lower right rear corner.
Power Heat
Vent
1"
WARNING:
A 1" clearance from the
fireplace enclosure is
required along the sides
and back of the fireplace.
Nail Down Plate (used to secure the fireplace to the floor)
Thermostat Wire Hole (on both sides)
1"
40"
1"
*Includes the required 1" clearance.
Gas Inlet (on both sides)
6 | 4050114 | 1 0 0 - 0 1 1 4 9 |
Travis Industries |