4 8 Optional Equipment (for qualified installers only)
3Follow the directions below to replace the orifices.
aSlide the three air shutters all the way to the left.
b
Use a 1/2” open end wrench to unscrew all three orifices.
1/2" Wrench
d
Screw the LP orifice in so the orifice shoulder protrudes 5/16” (indicating full insertion).
Manifold
Rear Orifice
Middle Orifice
Front Orifice
5/16”
c
Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices.
Look here for the orifice identification
LP NG
Front #55 #45
Middle #55 #43
Rear #55 #44