4 8 Optional Equipment (for qualified installers only)

3Follow the directions below to replace the orifices.

aSlide the three air shutters all the way to the left.

b

Use a 1/2” open end wrench to unscrew all three orifices.

1/2" Wrench

d

Screw the LP orifice in so the orifice shoulder protrudes 5/16” (indicating full insertion).

Manifold

Rear Orifice

Middle Orifice

Front Orifice

5/16”

c

Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices.

Look here for the orifice identification

LP NG

Front #55 #45

Middle #55 #43

Rear #55 #44

Travis Industries

4050114

1 0 0 - 0 1 1 4 9