NOTE:Two junction boxes are included - use the best box for your installation.

5 4 Optional Equipment (for qualified installers only)

6 Follow the directions below to wire the blower box.

a

Remove the cover from

 

the blower box.

Phillips

Screwdriver

b

Standard

Screwdriver

Insert sheathed cable through the cable clamp. After the wires have been connected tighten the clamp to secure the cable.

c

Attach the hot (black) and common (white) wires to the

leads coming from the wires (use wire nuts).

Secure the ground wire to the ground stud inside the d blower box by tightening the included nut over the

ground wire. Re-attach the cover removed in step "a".

Ground Wire

7Follow the directions below to wire the rheostat. NOTE: There are two types of junction boxes, use the appropriate junction box for your installation.

Force the sheathed cable through a one of the locking flaps on the

junction box (repeat for the other cable). Some force is needed. The flap will lock the cable in place.

From

Blower Box

Attach the common (white) wires b together. Attach the ground

(exposed or green) wires together. Then attach each of the hot (black) wires from the cables to the two wires on the rheostat (orientation does not matter). Carefully pack the wires into the junction box.

Attach the cover plate

c (either white or beige) with the included screws. Slide the knob (either white or beige) over the rheostat shaft.

Standard

Screwdriver

To

Fireplace

Travis Industries

4050114

1 0 0 - 0 1 1 4 9

Page 54
Image 54
FireplaceXtrordinair 44 DV XXL EF manual Follow the directions below to wire the blower box