Installation (for qualified installers only)

Clearances

When installed, walls in front of the fireplace must be a minimum 3-1/2" to the side of the faceplate.

Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.

Fireplace must be placed so the vents below and above the glass do not become blocked

Vertical Standoff

The vertical standoff above the fireplace must be erected prior to installation. See the illustration below for instructions.

The vertical standoff is shipped swiveled down. Rotate the standoff upwards into place.

Secure the standoff with the six screws.

1/4" Nutdriver

These lifting handles may be removed once the fireplace is in place.

7/16" Wrench

Nail or screw the fireplace to the floor through the holes on these brackets.