Air King Ventilation Hood Ducting, Wiring, Body, Damper, Hot Black, White from Lamp, Keyhole

Models: Ventilation Hood

1 16
Download 16 pages 28.17 Kb
Page 3
Image 3
Hood

 

Hood

 

Body

 

E-22A/RCD7

Damper

Tab

 

Figure 5

 

4.Install an approved wire connector to the electrical knockout of the hood and guide the electrical cable through the hood, allowing at least 6" of wire for connections and tighten.

NOTE: If installing into existing construction and you will not have access to the ductwork once the hood is in place, make ducting connections at this point. Refer to the Ducting Section for instructions.

5.Install the 4 mounting screw at the previously marked locations. Leave approximately 1/8" clearance. Slide the hood in place through the keyhole slots and align the front of the hood so that it is flush with the front of the cabinets. Tighten all screws securely (Figure 6).

 

Hot (Black)

White from Lamp

Ground

Figure 7

White from Motor

 

 

 

2.Install the wire compartment cover and tighten screw. Make sure all wiring is securely contained within the wire compartment.

Ducting

CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES.

WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

1.Connect the ducting to the hood’s duct collar and damper. Secure in place using tape to seal all joints (Figure 8).

1/8"

Keyhole

Figure 6

Wiring

CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

Figure 8

CAUTION: ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR ROOF CAP.

Finishing the Installation

1.Install the appropriate filters, sliding the back side of the filter into the tab and pressing the front of the filter into place (Figure 9).

1.

Connect the 2 loose White wires from the range hood to the White

 

 

wire from the supply, and the loose Black wire from the range hood

 

 

to the Black wire of the supply. Connect the ground wire (green or

 

 

bare) from the supply to the green ground screw of the hood. Use

 

 

approved methods for all connections (Figure 7).

 

 

NOTE: DO NOT disconnect any wiring that has already been crimped

 

with a wire connector from the factory.

 

 

 

 

Figure 9

 

6728002 Rev. E 1-07

www.airkinglimited.com

3

Page 3
Image 3
Air King Ventilation Hood manual Ducting, Wiring, Body, Damper, Hot Black, White from Lamp, White from Motor, Keyhole